Return to study ST001634 main page

MB Sample ID: SA138216

Local Sample ID:Sa_002
Subject ID:SU001711
Subject Type:Plant
Subject Species:Glycine max
Taxonomy ID:3847
Age Or Age Range:6 days

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001711
Subject Type:Plant
Subject Species:Glycine max
Taxonomy ID:3847
Age Or Age Range:6 days

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
Sa_002SA138216FL017576Wild-typeGenotype

Collection:

Collection ID:CO001704
Collection Summary:Soybean harasoy63 seeds were planted and grown for 6 days. Cotyledons were collected after 6 days for soybean hairy root transformation. After 21 days, transgenic soybean hairy roots were collected for metabolomics
Sample Type:Plant

Treatment:

Treatment ID:TR001724
Treatment Summary:No treatment, only effects of genotype compared to wild-type was investigated

Sample Preparation:

Sampleprep ID:SP001717
Sampleprep Summary:For metabolomics analysis, frozen hairy roots were ground with liquid nitrogen and extracted in methanol:water (80:20, v/v). The samples were sonicated on ice water bath for 15 min followed by centrifugation at 11,000×g for 10 min at ambient temperature. The supernatant (350 µL) was dried under nitrogen gas. The dried pellet was dissolved in 200 µL of 50% methanol containing 10 µg caffeine as an internal standard and filtered through a 0.45 µm syringe filter.
Sampleprep Protocol ID:jrenaud_SP_Sample_preparation.pdf

Combined analysis:

Analysis ID AN002670 AN002671
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290
Column Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um) Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH001965
Chromatography Summary:An Agilent 1290 HPLC using a Agilent Zorbax RRHD EclipsePlus (2.1 × 50 mm, 1.8 µm) was used to resolve the analytes.
Instrument Name:Agilent 1290
Column Name:Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um)
Column Temperature:35
Flow Gradient:0 min, 0% B; 0.5 min, 0% B; 3.5 min, 100% B; 6 min, 100% B; 6.5 min, 0% B
Flow Rate:0.300 uL/min
Sample Injection:5 uL
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Capillary Voltage:ESI+, 3.9kV; ESI-, 3.5 kV
Chromatography Type:Reversed phase

MS:

MS ID:MS002469
Analysis ID:AN002670
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Thermo.raw files were converted to .mzml format using Protewizard , with peak peaking filter applied. Features were detected using the XCMS package with the centWave method (ppm tolerance 3.0). The signal to noise threshold was set to 5, noise was set to 5×105 and pre-filter was set to five scans with a minimum 5,000 intensity. Retention time correction was conducted using the obiwarp method.. Grouping of features was set to those present in at least 0.1% of all samples (retention time deviation 5 s; m/z width, 0.015). The ‘fillPeaks’ function was used with default settings. Zero values were imputed by 2/3 the minimum peak area value of a specific feature across all samples. PCA plots were obtained by log transforming the imputed XCMS peak area values, and ‘pareto’ scaling in Rstudio. Volcano plots were also generated using the imputed XCMS peak area values. Compounds were identified by accurate mass, comparison of retention times to authentic standards or by accurate mass and also comparison of fragmentation patterns to MS/MS databases.
Ion Mode:POSITIVE
  
MS ID:MS002470
Analysis ID:AN002671
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Thermo.raw files were converted to .mzml format using Protewizard , with peak peaking filter applied. Features were detected using the XCMS package with the centWave method (ppm tolerance 3.0). The signal to noise threshold was set to 5, noise was set to 5×105 and pre-filter was set to five scans with a minimum 5,000 intensity. Retention time correction was conducted using the obiwarp method.. Grouping of features was set to those present in at least 0.1% of all samples (retention time deviation 5 s; m/z width, 0.015). The ‘fillPeaks’ function was used with default settings. Zero values were imputed by 2/3 the minimum peak area value of a specific feature across all samples. PCA plots were obtained by log transforming the imputed XCMS peak area values, and ‘pareto’ scaling in Rstudio. Volcano plots were also generated using the imputed XCMS peak area values. Compounds were identified by accurate mass, comparison of retention times to authentic standards or by accurate mass and also comparison of fragmentation patterns to MS/MS databases.
Ion Mode:NEGATIVE