Return to study ST001136 main page
MB Sample ID: SA078245
Local Sample ID: | Vehicle-5 |
Subject ID: | SU001197 |
Subject Type: | Mammal |
Subject Species: | Rattus norvegicus |
Taxonomy ID: | 10116 |
Genotype Strain: | ZDF rats |
Gender: | Not applicable |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001862 | AN001863 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | CE | CE |
Chromatography system | Agilent 7100 CE | Agilent 7100 CE |
Column | Fused silica capillary, i.d. 50 μm × 80 cm | Fused silica capillary, i.d. 50 μm × 80 cm |
MS Type | ESI | ESI |
MS instrument type | TOF | Triple quadrupole |
MS instrument name | Agilent 6210 TOF | Agilent 6460 QQQ |
Ion Mode | UNSPECIFIED | UNSPECIFIED |
Units | Concentration (nmol/g tissue) | Concentration (nmol/g tissue) |
MS:
MS ID: | MS001722 |
Analysis ID: | AN001862 |
Instrument Name: | Agilent 6210 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
MS Comments: | The spectrometer was scanned from m/z 50 to 1,000. Peaks were extracted using automatic integration software MasterHands (Keio University, Tsuruoka, Japan) in order to obtain peak information including m/z, migration time for CE-TOFMS measurement (MT) and peak area. Signal peaks corresponding to isotopomers, adduct ions, and other product ions of known metabolites were excluded, and remaining peaks were annotated with putative metabolites from the HMT metabolite database based on their MTs and m/z values determined by TOFMS. The tolerance range for the peak annotation was configured at ±0.5 min for MT and ±10 ppm for m/z. In addition, peak areas were normalized against those of the internal standards and then the resultant relative area values were further normalized by sample amount. |
Ion Mode: | UNSPECIFIED |
MS ID: | MS001723 |
Analysis ID: | AN001863 |
Instrument Name: | Agilent 6460 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | The spectrometer was scanned from m/z 50 to 1,000. Peaks were extracted using MasterHands, automatic integration software (Keio University, Tsuruoka, Yamagata, Japan) and MassHunter Quantitative Analysis B.04.00 (Agilent Technologies) in order to obtain peak information including m/z, peak area, and migration time (MT). Signal peaks were annotated according to the HMT metabolite database based on their m/z values with the MTs. The peak area of each metabolite was normalized with respect to the area of the internal standard and metabolite concentration was evaluated by standard curves with three-point calibrations using each standard compound. |
Ion Mode: | UNSPECIFIED |