Return to study ST001634 main page

MB Sample ID: SA138211

Local Sample ID:Sa_008
Subject ID:SU001711
Subject Type:Plant
Subject Species:Glycine max
Taxonomy ID:3847
Age Or Age Range:6 days

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002670 AN002671
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290
Column Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um) Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

MS:

MS ID:MS002469
Analysis ID:AN002670
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Thermo.raw files were converted to .mzml format using Protewizard , with peak peaking filter applied. Features were detected using the XCMS package with the centWave method (ppm tolerance 3.0). The signal to noise threshold was set to 5, noise was set to 5×105 and pre-filter was set to five scans with a minimum 5,000 intensity. Retention time correction was conducted using the obiwarp method.. Grouping of features was set to those present in at least 0.1% of all samples (retention time deviation 5 s; m/z width, 0.015). The ‘fillPeaks’ function was used with default settings. Zero values were imputed by 2/3 the minimum peak area value of a specific feature across all samples. PCA plots were obtained by log transforming the imputed XCMS peak area values, and ‘pareto’ scaling in Rstudio. Volcano plots were also generated using the imputed XCMS peak area values. Compounds were identified by accurate mass, comparison of retention times to authentic standards or by accurate mass and also comparison of fragmentation patterns to MS/MS databases.
Ion Mode:POSITIVE
  
MS ID:MS002470
Analysis ID:AN002671
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Thermo.raw files were converted to .mzml format using Protewizard , with peak peaking filter applied. Features were detected using the XCMS package with the centWave method (ppm tolerance 3.0). The signal to noise threshold was set to 5, noise was set to 5×105 and pre-filter was set to five scans with a minimum 5,000 intensity. Retention time correction was conducted using the obiwarp method.. Grouping of features was set to those present in at least 0.1% of all samples (retention time deviation 5 s; m/z width, 0.015). The ‘fillPeaks’ function was used with default settings. Zero values were imputed by 2/3 the minimum peak area value of a specific feature across all samples. PCA plots were obtained by log transforming the imputed XCMS peak area values, and ‘pareto’ scaling in Rstudio. Volcano plots were also generated using the imputed XCMS peak area values. Compounds were identified by accurate mass, comparison of retention times to authentic standards or by accurate mass and also comparison of fragmentation patterns to MS/MS databases.
Ion Mode:NEGATIVE
  logo