Return to study ST001997 main page
MB Sample ID: SA186801
Local Sample ID: | 8h 1+ |
Subject ID: | SU002078 |
Subject Type: | Cultured cells |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003257 | AN003258 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | peak area | peak area |
MS:
MS ID: | MS003029 |
Analysis ID: | AN003257 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Global metabolomics analyses were performed using a 3 min isocratic run in positive and negative ion modes (separate runs) as described previously (Nemkov et al., 2015, Nemkov et al., 2017); stable isotope tracing samples were analyzed using a 5 min C18 gradient in positive and negative ion modes (separate runs) as described (Nemkov et al., 2019, Gehrke et al., 2019). For all analyses, the MS scanned in MS1 mode across the m/z range of 65 to 950. Peaks were annotated (in conjunction with the KEGG database), integrated, and quality control performed using Maven (Princeton University) as described. Stable isotope tracing results were isotopically corrected for the natural abundance of 13C1, 13C2, 15N1, and 15N2 (Nemkov et al., 2017). |
Ion Mode: | POSITIVE |
MS ID: | MS003030 |
Analysis ID: | AN003258 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Global metabolomics analyses were performed using a 3 min isocratic run in positive and negative ion modes (separate runs) as described previously (Nemkov et al., 2015, Nemkov et al., 2017); stable isotope tracing samples were analyzed using a 5 min C18 gradient in positive and negative ion modes (separate runs) as described (Nemkov et al., 2019, Gehrke et al., 2019). For all analyses, the MS scanned in MS1 mode across the m/z range of 65 to 950. Peaks were annotated (in conjunction with the KEGG database), integrated, and quality control performed using Maven (Princeton University) as described. Stable isotope tracing results were isotopically corrected for the natural abundance of 13C1, 13C2, 15N1, and 15N2 (Nemkov et al., 2017). |
Ion Mode: | NEGATIVE |