Return to study ST002763 main page
MB Sample ID: SA291575
Local Sample ID: | A5_CE-MS |
Subject ID: | SU002870 |
Subject Type: | Bacteria |
Subject Species: | Haemophilus influenzae |
Genotype Strain: | Rd KW20 |
Species Group: | Bacteria |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004492 | AN004493 | AN004494 | AN004495 | AN004496 | AN004497 |
---|---|---|---|---|---|---|
Analysis type | MS | MS | MS | MS | MS | MS |
Chromatography type | GC | CE | Reversed phase | Reversed phase | Reversed phase | Reversed phase |
Chromatography system | Agilent 7890B | Agilent 7100 CE | Agilent 1290 Infinity | Agilent 1290 Infinity | Agilent 1290 Infinity | Agilent 1290 Infinity |
Column | Agilent DB5-MS (30m x 0.25mm, 0.25um) | fused silica capillary (70 cm; 50 um i.d.), Agilent Technologies | Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) | Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) | Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) | Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) |
MS Type | EI | ESI | ESI | ESI | ESI | ESI |
MS instrument type | QTOF | TOF | QTOF | QTOF | QTOF | QTOF |
MS instrument name | Agilent 7250 | Agilent 6224 TOF | Agilent 6545 QTOF | Agilent 6545 QTOF | Agilent 6545 QTOF | Agilent 6545 QTOF |
Ion Mode | UNSPECIFIED | POSITIVE | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | raw abundance | raw abundance | raw abundance | raw abundance | raw abundance |
MS:
MS ID: | MS004239 |
Analysis ID: | AN004492 |
Instrument Name: | Agilent 7250 |
Instrument Type: | QTOF |
MS Type: | EI |
MS Comments: | 70 eV EI source, Full MS scan, m/z range from 45 to 650. Acquisition rate of 6.67 spectra/s Data processed using Agilent MassHunter Unknowns Analysis and Agilent MassHunter Quantitative Analysis. Feature assignment performed by comparison with Fiehn exact mass, NIST, and in-house exact mass libraries. |
Ion Mode: | UNSPECIFIED |
MS ID: | MS004240 |
Analysis ID: | AN004493 |
Instrument Name: | Agilent 6224 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
MS Comments: | drying gas T = 200 ºC; drying gas flow rate = 10 L/min; nebulizer pressure = 10 psi; capillary V = 5500 V; fragmentor V = 125 V; skimmer V = 65 V; octopole RFV = 650 V; Acquisition mode: Full-MS scan, m/z range from 70 to 1000; acquisition rate = 1.36 spectra/s. Data processed with Agilent MassHunter Profinder B.10.00, feature assignment performed with CEU Mass Mediator Exp RMT Search and CEU Mass Mediator Batch Search. |
Ion Mode: | POSITIVE |
MS ID: | MS004241 |
Analysis ID: | AN004494 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Drying gas T = 300 ºC; drying gas flow rate = 12 L/min; Capillary V = 3500 V; fragmentor V = 150 V; skimmer V = 65 V; octopole RFV = 750 V. MS acquisition mode = Full MS scan, mz range = 50 to 3000; acquisition rate = 3.5 spectra/s. Data processed with Agilent MassHunter Profinder B.10.00 and Agilent MassHunter Qualitative Analysis (B.08.00). Feature annotation performed with Agilent MassHunter Lipid Annotator (v.1.0) and CEU Mass Mediator Batch Search. |
Ion Mode: | POSITIVE |
MS ID: | MS004242 |
Analysis ID: | AN004495 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Drying gas T = 300 ºC; drying gas flow rate = 12 L/min; Capillary V = 3500 V; fragmentor V = 150 V; skimmer V = 65 V; octopole RFV = 750 V. MS acquisition mode = Auto MS/MS, mz range = 50 to 3000; acquisition rate = 3.5 spectra/s. Data processed with Agilent MassHunter Profinder B.10.00 and Agilent MassHunter Qualitative Analysis (B.08.00). Feature annotation performed with Agilent MassHunter Lipid Annotator (v.1.0) and CEU Mass Mediator Batch Search. |
Ion Mode: | NEGATIVE |
MS ID: | MS004243 |
Analysis ID: | AN004496 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Drying gas T = 300 ºC; drying gas flow rate = 12 L/min; Capillary V = 3500 V; fragmentor V = 150 V; skimmer V = 65 V; octopole RFV = 750 V. MS acquisition mode = Auto MS/MS, isolation width = narrow (1.3 Da); collision energy (ramp) = 3.8; offset (ramp) = 4 6. Data processed with Agilent MassHunter Profinder B.10.00 and Agilent MassHunter Qualitative Analysis (B.08.00). Feature annotation performed with Agilent MassHunter Lipid Annotator (v.1.0) |
Ion Mode: | POSITIVE |
MS ID: | MS004244 |
Analysis ID: | AN004497 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Drying gas T = 300 ºC; drying gas flow rate = 12 L/min; Capillary V = 3500 V; fragmentor V = 150 V; skimmer V = 65 V; octopole RFV = 750 V. MS acquisition mode = Iterative auto MS/MS, isolation width = narrow (1.3 Da); collision energy (ramp) = 3.8; offset (ramp) = 4 6. Data processed with Agilent MassHunter Profinder B.10.00 and Agilent MassHunter Qualitative Analysis (B.08.00). Feature annotation performed with Agilent MassHunter Lipid Annotator (v.1.0) |
Ion Mode: | NEGATIVE |