Summary of Study ST000045

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000044. The data can be accessed directly via it's Project DOI: 10.21228/M8D59R This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000045
Study TitlePlasma metabolomics: Comparison of non-diabetic controls with T1D patients
Study TypeDrug effect study
Study SummaryNon-diabetic controls whose metabolites were compared to T1D patients with and without insulin. Seven C-peptide–negative T1D subjects were studied on two occasions: one during insulin treatment and the other following withdrawal of insulin for 8 h and compared with matched healthy ND participants
Institute
Mayo Clinic
DepartmentEndocrinology
Last NameNair
First NameSreekumaran
EmailDasari.Surendra@mayo.edu
Submit Date2014-03-24
Num Groups1
Total Subjects7
Raw Data AvailableYes
Raw Data File Type(s)d
Uploaded File Size66 G
Analysis Type DetailLC-MS
Release Date2014-04-20
Release Version1
Sreekumaran Nair Sreekumaran Nair
https://dx.doi.org/10.21228/M8D59R
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000072 AN000073 AN000074 AN000075
Analysis type MS MS MS MS
Chromatography type Reversed phase HILIC Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type TOF TOF TOF TOF
MS instrument name Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units Raw MS Intensities Raw MS Intensities Raw MS Intensities Raw MS Intensities

Chromatography:

Chromatography ID:CH000047
Chromatography Summary:C18
Chromatography Comments:The liquid chromatography platform consisted of an Acquity UPLC system (Waters, Milford, MA). Plasma metabolite separation was achieved using both hydrophilic interaction chromatography (ethylene-bridged hybrid 2.1 150 mm, 1.7 m; Waters) and reversed-phase liquid chromatography C18 (high-strength silica 2.1 150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. Reverse-phase chromatography was performed using 99% solvent A (5 mmol/L NH4 acetate, 0.1% formic acid, and 1% acetonitrile) to 100% solvent B (95% acetonitrile with 0.1% formic acid). The gradient was 0 min, 0% B; 1 min, 0% B; 3 min, 5% B; 13.0 min, 100% B; 16 min, 100% B; 16.5 min, 0% B; and 20 min, 0% B. Other LC parameters were injection volume 5 L and column temperature 50C. Each sample was injected in triplicate with blank injections between each sample. Quality controls and standards were run at the beginning and end of the sequence.
Instrument Name:Waters Acquity
Column Name:Waters high-strength silica (150 x 2.1mm,1.8um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH000048
Chromatography Summary:HILIC
Chromatography Comments:The liquid chromatography platform consisted of an Acquity UPLC system (Waters, Milford, MA). Plasma metabolite separation was achieved using both hydrophilic interaction chromatography (ethylene-bridged hybrid 2.1 150 mm, 1.7 m; Waters) and reversed-phase liquid chromatography C18 (high-strength silica 2.1 150 mm, 1.8 m; Waters). For each column, the run time was 20 min at a flow rate of 400 L/min. The hydrophilic interaction chromatography gradient was as follows: 0 min, 100% B; 1 min, 100% B; 5 min, 90% B; 13.0 min, 0% B; 16 min, 0% B; 16.5 min, 100% B; and 20 min, 100% B. Other LC parameters were injection volume 5 L and column temperature 50C. Each sample was injected in triplicate with blank injections between each sample. Quality controls and standards were run at the beginning and end of the sequence.
Instrument Name:Waters Acquity
Column Name:Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
Chromatography Type:HILIC