Summary of Study ST000318

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000257. The data can be accessed directly via it's Project DOI: 10.21228/M8K306 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000318
Study TitleAllantoin differences in Synechococcus cells grown in high versus low lightgrowth
Study SummaryThis experimented consisted of analysis of 500-1000ml of Synechococcus dense cell cultures grown in high versus low light. The goal was to see any differences in the metabolites between the two treatments, especially with respect to Allantoin.
Institute
University of California, Davis
DepartmentGenome and Biomedical Sciences Facility
LaboratoryWCMC Metabolomics Core
Last NameFiehn
First NameOliver
Address1315 Genome and Biomedical Sciences Facility, 451 Health Sciences Drive, Davis, CA 95616
Emailofiehn@ucdavis.edu
Phone(530) 754-8258
Submit Date2014-11-14
Num Groups4
Total Subjects12
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2016-01-27
Release Version1
Oliver Fiehn Oliver Fiehn
https://dx.doi.org/10.21228/M8K306
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000505 AN000506
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Unspecified Unspecified
Column Waters Acquity CSH C18 (100 x 2.1mm,1.7um) Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units Peak height Peak height

Chromatography:

Chromatography ID:CH000356
Chromatography Summary:UPLC
Methods Filename:Data_Dictionary_Fiehn_laboratory_CSH_QTOF_lipidomics_05-29-2014.pdf
Instrument Name:Unspecified
Column Name:Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
Column Pressure:450-850 bar
Column Temperature:65 C
Flow Gradient:15% B to 99% B
Flow Rate:0.6 mL/min
Internal Standard:See data dictionary
Retention Time:See data dictionary
Sample Injection:1.67 uL
Solvent A:60% acetonitrile/40% water; 10mM formic acid; 10mM ammonium formate
Solvent B:90% isopropanol/10% acetonitrile; 10mM formic acid; 10mM ammonium formate
Analytical Time:13 min
Capillary Voltage:3500
Time Program:15 min
Weak Wash Solvent Name:Isopropanol
Weak Wash Volume:5 seconds
Strong Wash Solvent Name:Isopropanol
Target Sample Temperature:Autosampler temp 4 C
Randomization Order:Excel
Chromatography Type:Reversed phase
  logo