Summary of Study ST000402

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000314. The data can be accessed directly via it's Project DOI: 10.21228/M8V59S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000402
Study TitleImpact of glucose on the central metabolome of C. minutissima
Study SummaryAxenic Chlorella minutissima (UTEX 2341) was grown under mixotrophic and autotrophic conditions to compare metabolome differences. The purpose of this study was to understand how glucose impacted the central metabolome of C. minutissima.
Institute
University of California, Davis
DepartmentGenome and Biomedical Sciences Facility
LaboratoryWCMC Metabolomics Core
Last NameFiehn
First NameOliver
Address1315 Genome and Biomedical Sciences Facility, 451 Health Sciences Drive, Davis, CA 95616
Emailofiehn@ucdavis.edu
Phone(530) 754-8258
Submit Date2016-05-16
Raw Data AvailableYes
Raw Data File Type(s)peg
Analysis Type DetailGC-MS
Release Date2016-06-18
Release Version1
Oliver Fiehn Oliver Fiehn
https://dx.doi.org/10.21228/M8V59S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000641
Analysis type MS
Chromatography type GC
Chromatography system Agilent 6890N
Column Restek Corporation Rtx-5Sil MS
MS Type EI
MS instrument type GC Ion Trap
MS instrument name Varian 210-MS GC Ion Trap
Ion Mode POSITIVE
Units counts

Chromatography:

Chromatography ID:CH000466
Methods Filename:Data_Dictionary_Fiehn_laboratory_GCTOF_MS_primary_metabolism_10-15-2013_general.pdf
Instrument Name:Agilent 6890N
Column Name:Restek Corporation Rtx-5Sil MS
Column Pressure:7.7 PSI
Column Temperature:50-330C
Flow Rate:1 ml/min
Injection Temperature:50 C ramped to 250 C by 12 C/s
Sample Injection:0.5 uL
Oven Temperature:50°C for 1 min, then ramped at 20°C/min to 330°C, held constant for 5 min
Transferline Temperature:230C
Washing Buffer:Ethyl Acetate
Sample Loop Size:30 m length x 0.25 mm internal diameter
Randomization Order:Excel generated
Chromatography Type:GC
  logo