Summary of Study ST000669

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000472. The data can be accessed directly via it's Project DOI: 10.21228/M82028 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000669
Study TitleCharacterization of Retinal Exudates in Coats Disease - lipid profile
Study TypeMS analysis
Study SummaryThe aim of our study is to characterize the retinal lipid exudates through lipidomic assays. Lipidomic analysis will quantify and identify the retinal lipid exudates and provide a `lipid profile? of the exudates. The characterization of the retinal lipids will help in further understanding the pathogenesis of Coat?s disease. It may allow us to identify and therapeutically target a metabolic pathway to prevent retinal exudation abnormal in Coat?s disease.
Institute
University of Michigan
DepartmentBiomedical Research Core Facilities
LaboratoryMetabolomics core
Last NameKachman
First NameMaureen
Address6300 Brehm Tower, 1000 Wall Street, Ann Arbor, MI 48105-5714
Emailmkachman@med.umich.edu
Phone(734) 232-8175
Submit Date2017-06-05
Num Groups11
Total Subjects4
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2017-12-06
Release Version1
Maureen Kachman Maureen Kachman
https://dx.doi.org/10.21228/M82028
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001024 AN001025
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Shimadzu CTO-20A Nexera X2 Shimadzu CTO-20A Nexera X2
Column Waters Acquity HSS T3 (50 x 2.1mm,1.8um) Waters Acquity HSS T3 (50 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type Triple TOF Triple TOF
MS instrument name ABI Sciex 5600+ TripleTOF ABI Sciex 5600+ TripleTOF
Ion Mode NEGATIVE POSITIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH000732
Instrument Name:Shimadzu CTO-20A Nexera X2
Column Name:Waters Acquity HSS T3 (50 x 2.1mm,1.8um)
Column Temperature:55
Flow Rate:0.400uL/min
Solvent A:40% acetonitrile/60% water; 10 mM ammonium acetate
Solvent B:10% acetonitrile/5% water/85% isopropanol; 10 mM ammonium acetate
Chromatography Type:Reversed phase
  logo