Summary of Study ST001073

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000718. The data can be accessed directly via it's Project DOI: 10.21228/M8VT2P This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001073
Study TitleLipid profiling of Wnt3a-induced optic nerve regeneration
Study Typeuntargeted lipid profiling
Study SummaryWe analyzed lipid profiles of mouse retina and optic nerve for 2 time points - 7 and 15 days post-crush, and 3 conditions - intact control, optic nerve crush + vehicle (saline) intravitreal injection, optic nerve crush + 20 ng of Wnt3a injection.
Institute
University of Miami
DepartmentOphthalmology, Bascom Palmer Eye Institute
LaboratorySanjoy K. Bhattacharya lab
Last NameBhattacharya
First NameSanjoy
AddressBascom Palmer Eye Institute (McKnight Bldg.), 1638 NW 10th Avenue, Suite 707A, University of Miami, Miami, FL, 33136
Emailsbhattacharya@med.miami.edu
Phone305-482-4103
Submit Date2018-10-03
Num Groups6
Total Subjects12
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2018-12-11
Release Version1
Sanjoy Bhattacharya Sanjoy Bhattacharya
https://dx.doi.org/10.21228/M8VT2P
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001755
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Accela 600
Column Thermo Acclaim C30 (150 x 2.1mm,3um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode UNSPECIFIED
Units relative abundance (main area)

Chromatography:

Chromatography ID:CH001239
Chromatography Summary:Reversed phase chromatographic separation utilized Accela Autosampler (Thermo), Accela 600 pump (Thermo) and Acclaim C30 column: 3 µm, 2.1x150 mm (Thermo). The column temperature was maintained at 30˚C and tray temperature at 20˚C. Solvent A was composed of 10 mM ammonium acetate (LC-MS grade) in 60:40 methanol:water (LC-MS grade) with 0.2% formic acid (FA; LC-MS grade). Solvent B was composed of 10 mM ammonium acetate with 60:40 methanol:chloroform with 0.2% FA. The flow rate was 260 µL/min and injection volume was 10 µL. The gradient was 35-100% solvent B over 13.0 min, 100% solvent B over 13.0-13.8 min, 100-35% solvent B over 13.8-14.5 min, 35% solvent B over 14.5-18.0 min, 0% solvent B over 18.0-20.0 min.
Instrument Name:Thermo Accela 600
Column Name:Thermo Acclaim C30 (150 x 2.1mm,3um)
Column Temperature:30˚C
Flow Gradient:The gradient was 35-100% solvent B over 13.0 min, 100% solvent B over 13.0-13.8 min, 100-35% solvent B over 13.8-14.5 min, 35% solvent B over 14.5-18.0 min, 0% solvent B over 18.0-20.0 min.
Flow Rate:260 µL/min
Sample Injection:10 µL
Solvent A:60% methanol/40% water; 0.2% formic acid; 10 mM ammonium acetate
Solvent B:60% methanol/40% chloroform; 0.2% formic acid; 10 mM ammonium acetate
Analytical Time:20 min
Washing Buffer:methanol
Chromatography Type:Reversed phase