This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000809. The data can be accessed directly via it's Project DOI: 10.21228/M83X38 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001202
Study TitlePeroxide antimalarial treatment timecourse on ring-stage P. falciparum parasites
Study SummaryRed blood cells (RBCs) infected with ring stage P. falciparum parasites (3D7 strain) at 10% parasitaemia and 2% haematocrit were treated with OZ277 (1 uM), OZ439 (1 uM), DHA (300 nM) or vehicle (0.03% DMSO). This was a 5-timepoint study, with samples taken 0, 1.5, 3, 6 and 9 h after drug or vehicle addition. Samples treated with vehicle acted as the untreated control. Samples from drug treated uninfected RBCs were also taken to ensure the observed drug effects were parasite specific.
Institute
Monash University
Last NameGiannangelo
First NameCarlo
Address381 Royal Parade, Parkville, Victoria, 3052, Australia
Emailcarlo.giannangelo@monash.edu
Phone99039282
Submit Date2019-06-24
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2019-07-17
Release Version1
Carlo Giannangelo Carlo Giannangelo
https://dx.doi.org/10.21228/M83X38
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002000 AN002001
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column SeQuant ZIC-pHILIC (150 x 2.1mm,5um) SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak intensity Peak intensity

Chromatography:

Chromatography ID:CH001447
Chromatography Summary:The 32 min gradient HPLC run was from 80% B to 50% B over 15 min, then to 5% B at 18 min, followed by a wash with 5% B for 3 min and re-equilibrated with 80% B at a flow rate of 0.3 mL/min.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
Solvent A:100% water; 20 mM ammonium carbonate
Solvent B:100% acetonitrile
Chromatography Type:HILIC