Summary of Study ST001262

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000847. The data can be accessed directly via it's Project DOI: 10.21228/M86H4F This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001262
Study TitleThe impact of tobacco smoke exposure and environmental exposures on the pulmonary microbiome of critically ill children
Study SummaryThis project evaluates the effects of tobacco smoke exposure (TSE) on the pediatric lung microbiome in critically ill children. The impact of TSE on the airway microbiome of critically ill, mechanically ventilated pediatric patients will be determined by through clinical outcomes and analysis of urinary and plasma metabolomes to identify other environmental exposures contributing to the alteration of the pediatric microbiome.
Institute
Emory University
DepartmentSchool of Medicine
LaboratoryClincal Biomarkers Laboratory
Last NameUppal
First NameKaran
AddressNA
Emailkuppal2@emory.edu
Phone(404) 727 5027
Submit Date2019-06-25
Total Subjects367
Study CommentsBoth CHEAR pooled urine samples and Clinical Biomarker Laboratory pooled plasma samples were used
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Chear StudyYes
Analysis Type DetailLC-MS
Release Date2021-08-31
Release Version1
Karan Uppal Karan Uppal
https://dx.doi.org/10.21228/M86H4F
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002094 AN002095
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Dionex UltiMate 3000 Dionex UltiMate 3000
Column Waters XBridge BEH Amide XP HILIC (50 x 2.1mm x 2.5um) with Thermo Accucore HILIC guard Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH001529
Chromatography Summary:The HILIC column is operated parallel to reverse phase column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6-port switching valves. During operation of HILIC separation method, the MS is operated in positive ion mode and 10 microliters of sample is injected onto the HILIC column while the reverse phase column is flushing with wash solution. Flow rate is maintained at 0.35 mL/min until 1.5 min, increased to 0.4 mL/min at 4 min and held for 1 min. Solvent A is 100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C is 2% formic acid (v/v) in LC-MS grade water. Initial mobile phase conditions are 22.5% A, 75% B, 2.5% C hold for 1.5 min, with linear gradient to 77.5% A, 20% B, 2.5% C at 4 min, hold for 1 min, resulting in a total analytical run time of 5 min. During the flushing phase (reverse phase analytical separation), the HILIC column is equilibrated with a wash solution of 77.5% A, 20% B, 2.5% C.
Methods ID:2% formic acid in LC-MS grade water
Methods Filename:20160920_posHILIC120kres5min_ESI_c18negwash.meth
Chromatography Comments:Triplicate injections for each chromatography mode
Instrument Name:Dionex UltiMate 3000
Column Name:Waters XBridge BEH Amide XP HILIC (50 x 2.1mm x 2.5um) with Thermo Accucore HILIC guard
Column Temperature:60C
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Sample Loop Size:15 uL
Sample Syringe Size:100 uL
Chromatography Type:HILIC
  
Chromatography ID:CH001530
Chromatography Summary:The C18 column is operated parallel to the HILIC column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6- port switching valves. During operation of the "C18 method, the MS is operated in negative ion mode and 10 μL of sample is" injected onto the C18 column while the HILIC column is flushing with wash "solution. Flow rate is maintained at 0.4 mL/min until 1.5 min, increased to 0.5" "mL/min at 2 min and held for 3 min. Solvent A is 100% LC-MS grade water, solvent" B is 100% LC-MS grade acetonitrile and solvent C is 10mM ammonium acetate in "LC-MS grade water. Initial mobile phase conditions are 60% A, 35% B, 5% C hold" "for 0.5 min, with linear gradient to 0% A, 95% B, 5% C at 1.5 min, hold for 3.5" "min, resulting in a total analytical run time of 5 min. During the flushing" "phase (HILIC analytical separation), the C18 column is equilibrated with a wash" "solution of 0% A, 95% B, 5% C until 2.5 min, followed by an equilibration" "solution of 60% A, 35% B, 5% C for 2.5 min."
Methods ID:10mM ammonium acetate in LC-MS grade water
Methods Filename:20160920_negC18120kres5min_ESI_HILICposwash.meth
Instrument Name:Dionex UltiMate 3000
Column Name:Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
Column Temperature:60C
Flow Rate:0.4 mL/min for 1.5 min; linear increase to 0.5 mL/min at 2 min held for 3 min
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Sample Loop Size:15 uL
Sample Syringe Size:100 uL
Chromatography Type:Reversed phase
  logo