Summary of Study ST001380

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000944. The data can be accessed directly via it's Project DOI: 10.21228/M8P41V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001380
Study TitleFast and sensitive flow-injection mass spectrometry metabolomics by analyzing sample specific ion distributions
Study SummaryMass spectrometry based metabolomics is a widely used approach in biotechnology and biomedical research. However, current methods coupling mass spectrometry with chromatography are time-consuming and not suitable for high-throughput analysis of thousands of samples. An alternative approach is flow-injection mass spectrometry (FI-MS) in which samples are directly injected to the ionization source. Here, we show that the sensitivity of Orbitrap FI-MS metabolomics methods is limited by ion competition effect in the detection system. We describe an approach for overcoming this effect by analyzing the distribution of ion m/z values and computationally determining a series of optimal scan ranges. This enables reproducible detection of ~9,000 and ~10,000 m/z features in metabolomics and lipidomics analysis of serum samples, respectively, with a sample scan time of ~15 seconds and duty time of ~30 seconds; a ~50% increase versus current spectral-stitching FI-MS. This approach facilitates high-throughput metabolomics for a variety of applications, including biomarker discovery and functional genomics screens.
Institute
Technion – Israel Institute of Technology
Last NameShlomi
First NameTomer
AddressTechnion
Emailtomersh@cs.technion.ac.il
Phone+972-77-8871497
Submit Date2020-05-17
Raw Data AvailableYes
Raw Data File Type(s)mzXML, raw(Thermo)
Analysis Type DetailMS(Dir. Inf.)
Release Date2020-05-22
Release Version1
Tomer Shlomi Tomer Shlomi
https://dx.doi.org/10.21228/M8P41V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002300
Analysis type MS
Chromatography type None (Direct infusion)
Chromatography system none
Column none
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode UNSPECIFIED
Units intensity

Chromatography:

Chromatography ID:CH001690
Instrument Name:none
Column Name:none
Chromatography Type:None (Direct infusion)