Summary of Study ST001606

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001031. The data can be accessed directly via it's Project DOI: 10.21228/M8F39C This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001606
Study TitleAromatic amino acid metabolism by the anaerobic gut bacterium Clostridium sporogenes
Study SummaryGerm-free mice were mono-colonized with wild-type Clostridium sporogenes or its isogenic phenyllactate dehydratase (fldC) mutant. Feces, cecal contents, serum, and urine were collected for untargeted GC-TOF analysis.
Institute
Stanford University
LaboratoryDodd
Last NamePruss
First NameKali
Address300 Pasteur Drive, Lane 235
Emailkmpruss@stanford.edu
Phone6507212961
Submit Date2020-11-20
Raw Data AvailableYes
Raw Data File Type(s)cdf
Analysis Type DetailGC-MS
Release Date2020-12-01
Release Version1
Kali Pruss Kali Pruss
https://dx.doi.org/10.21228/M8F39C
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002639
Analysis type MS
Chromatography type GC
Chromatography system Agilent 6890 GC
Column Restek Rtx-5Sil (30m x 0.25mm,0.25m)
MS Type EI
MS instrument type GC-TOF
MS instrument name Leco Pegasus IV TOF
Ion Mode POSITIVE
Units peak area

Chromatography:

Chromatography ID:CH001949
Chromatography Summary:Injector conditions: Agilent 6890 GC is equipped with a Gerstel automatic liner exchange system (ALEX) that includes a multipurpose sample (MPS2) dual rail, and a Gerstel CIS cold injection system (Gerstel, Muehlheim, Germany) with temperature program as follows: 50°C to 275°C final temperature at a rate of 12 °C/s and hold for 3 minutes. Injection volume is 0.5 μl with 10 μl/s injection speed on a splitless injector with purge time of 25 seconds. Liner (Gerstel #011711-010-00) is changed after every 10 samples, (using the Maestro1 Gerstel software vs. 1.1.4.18). Before and after each injection, the 10 μl injection syringe is washed three times with 10 μl ethyl acetate. Gas Chromatography conditions: A 30 m long, 0.25 mm i.d. Rtx-5Sil MS column (0.25 μm 95% dimethyl 5% diphenyl polysiloxane film) with additional 10 m integrated guard column is used (Restek, Bellefonte PA). 99.9999% pure Helium with built-in purifier (Airgas, Radnor PA) is set at constant flow of 1 ml/min. The oven temperature is held constant at 50°C for 1 min and then ramped at 20°C/min to 330°C at which it is held constant for 5 min.
Chromatography Comments:0 m long, 0.25 mm i.d. Rtx-5Sil MS column (0.25 μm 95% dimethyl 5% diphenyl polysiloxane film))
Instrument Name:Agilent 6890 GC
Column Name:Restek Rtx-5Sil (30m x 0.25mm,0.25m)
Chromatography Type:GC
  logo