This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001045. The data can be accessed directly via it's Project DOI: 10.21228/M8MQ3V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001634
Study TitleA combinatorial action of GmMYB176 and bZIP controls isoflavonoid biosynthesis in soybean.
Study SummaryThis study identified how the GmMYB176 protein complex affects the metabolome of soybean hairy roots using non-targeted high resolution mass spectrometry.
Institute
Agriculture and Agri-Food Canada
Last NameRenaud
First NameJustin
Address1391 Sandford Street, London, Ontario, N5V 4T3, Canada
Emailjustin.renaud@canada.ca
Phone519-953-6698
Submit Date2020-12-17
Num Groups2
Total Subjects10
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2021-01-07
Release Version1
Justin Renaud Justin Renaud
https://dx.doi.org/10.21228/M8MQ3V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002670 AN002671
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290
Column Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um) Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH001965
Chromatography Summary:An Agilent 1290 HPLC using a Agilent Zorbax RRHD EclipsePlus (2.1 × 50 mm, 1.8 µm) was used to resolve the analytes.
Instrument Name:Agilent 1290
Column Name:Agilent Zorbax RRHD EclipsePlus (50 x 2.1mm,1.8um)
Column Temperature:35
Flow Gradient:0 min, 0% B; 0.5 min, 0% B; 3.5 min, 100% B; 6 min, 100% B; 6.5 min, 0% B
Flow Rate:0.300 uL/min
Sample Injection:5 uL
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Capillary Voltage:ESI+, 3.9kV; ESI-, 3.5 kV
Chromatography Type:Reversed phase