Summary of Study ST001719

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001053. The data can be accessed directly via it's Project DOI: 10.21228/M8KQ59 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001719
Study TitleMetabolomics Analysis of Philadelphia Cohort - Update (part-I)
Study TypeMetabolomics Analysis
Study SummaryGlobal metabolomics analysis of Philadelphia cohort
Institute
The Wistar Institute
Last NameAbdel-Mohsen
First NameMohamed
Address3601 Spruce St, Philadelphia, PA 19104
Emailmmohsen@wistar.org
Phone215-898-6008
Submit Date2021-01-07
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2021-05-25
Release Version1
Mohamed Abdel-Mohsen Mohamed Abdel-Mohsen
https://dx.doi.org/10.21228/M8KQ59
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002802
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Vanquish
Column SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive HF-X Orbitrap
Ion Mode UNSPECIFIED
Units Peak Area

Chromatography:

Chromatography ID:CH002070
Chromatography Summary:Hydrophilic interaction liquid chromatography (HILIC) was performed at 0.2 ml/min on a ZIC-pHILIC column (2.1 mm × 150 mm, EMD Millipore) at 45 °C. Solvent A was 20 mM ammonium carbonate, 0.1% ammonium hydroxide, pH 9.2, and solvent B was acetonitrile. The gradient was 85% B for 2 min, 85% B to 20% B over 15 min, 20% B to 85% B over 0.1 min, and 85% B for 8.9 min. The autosampler was held at 4 °C. For each analysis, 4 µl of sample was injected.
Instrument Name:Thermo Vanquish
Column Name:SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
Flow Gradient: 85% B for 2 min, 85% B to 20% B over 15 min, 20% B to 85% B over 0.1 min, and 85% B for 8.9 min.
Solvent A:100% water; 20 mM ammonium carbonate; 0.1% ammonium hydroxide, pH 9.2
Solvent B:100% acetonitrile
Chromatography Type:HILIC