Summary of Study ST003328

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002070. The data can be accessed directly via it's Project DOI: 10.21228/M81Z4C This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003328
Study TitleIncreased Cholesterol Synthesis Drives Neurotoxicity in Patient Stem Cell-Derived Model of Multiple Sclerosis - cellular lipidomics
Study SummaryLipidomics analysis was performed on directly induced neural stem/progenitor cell (iNSC) lines derived from fibroblasts of patients with progressive multiple sclerosis (PMS) versus age matched controls (AMC) treated or untreated with cholesterol synthesis inhibitor simvastatin.
Institute
University of Colorado Denver
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2024-07-17
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-08-08
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M81Z4C
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005452 AN005453
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (30 x 2.1mm,1.7um) Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH004139
Chromatography Summary:Negative C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-3 min 10-95% B at 0.3 mL/min, 3-4.2 min hold at 95% B at 0.3 mL/min, 4.2-4.3 min drop to 10% B at 0.45 mL/min, 4.3-4.9 min hold at 10%B while lowering flow rate to 0.4 mL/min, 4.9-5 min hold at 10%B while lowering flow rate to 0.3 mL/min.
Flow Rate:0.3 mL/min - 0.45 mL/min
Sample Injection:10 uL
Solvent A:75% water/25% acetonitrile; 5 mM ammonium acetate
Solvent B:90% isopropanol/10% acetonitrile; 5 mM ammonium acetate
Chromatography Type:Reversed phase
  
Chromatography ID:CH004140
Chromatography Summary:Positive C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-3 min 30-100% B at 0.3 mL/min, 3-4.2 min hold at 100% B at 0.3 mL/min, 4.2-4.3 min 100-30% B at 0.4 mL/min, 4.3-4.9 min hold at 30%B and 0.4 mL/min, 4.9-5 min hold at 30%B while lowering flow rate to 0.3 mL/min
Flow Rate:0.3 mL/min - 0.4 mL/min
Sample Injection:10 uL
Solvent A:75% water/25% acetonitrile; 5 mM ammonium acetate
Solvent B:90% isopropanol/10% acetonitrile; 5 mM ammonium acetate
Chromatography Type:Reversed phase
  logo