Summary of Study ST001778

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001131. The data can be accessed directly via it's Project DOI: 10.21228/M8HD7B This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001778
Study TitleComparison of High-Resolution Fourier Transform Mass Spectrometry Platforms for Metabolite Annotation
Study TypeMS based metabolomics
Study SummaryFourier transform ion cyclotron resonance (FT-ICR) and Orbitrap mass spectrometry (MS) are among the highest-performing analytical platforms in metabolomics. Their high mass measurement accuracy and mass resolving power enable detailed investigation of biological metabolomes. Non-targeted MS experiments, however, yield extremely complex datasets that make metabolite annotation very challenging, if not impossible. High-resolution accurate mass measurements greatly facilitate this process by reducing mass errors and spectral overlaps. When applied together with relative isotopic abundance (RIA) measurements, heuristic rules, and constraints during searches, the number of candidate elemental formula(s) can be significantly reduced. Here, we evaluate the performance of two leading analytical MS platforms, Orbitrap ID-X and 12T solariX FT-ICR mass spectrometers, in terms of mass accuracy and RIA measurements, and how these factors affect the assignment of the correct elemental formulae in metabolite annotation.
Institute
Georgia Institute of Technology
DepartmentChemistry
LaboratoryFernández
Last NameHuang
First NameDanning
Address901 Atlantic Dr NE
Emaildhuang74@gatech.edu
Phone4045127523
Submit Date2021-05-05
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailICR-MS
Release Date2022-05-05
Release Version1
Danning Huang Danning Huang
https://dx.doi.org/10.21228/M8HD7B
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Collection:

Collection ID:CO001848
Collection Summary:PD1074 C. elegans samples (~10 mg) were collected and lyophilized.
Sample Type:Worms
Storage Conditions:-80℃