Summary of Study ST000045

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000044. The data can be accessed directly via it's Project DOI: 10.21228/M8D59R This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000045
Study TitlePlasma metabolomics: Comparison of non-diabetic controls with T1D patients
Study TypeDrug effect study
Study SummaryNon-diabetic controls whose metabolites were compared to T1D patients with and without insulin. Seven C-peptide–negative T1D subjects were studied on two occasions: one during insulin treatment and the other following withdrawal of insulin for 8 h and compared with matched healthy ND participants
Institute
Mayo Clinic
DepartmentEndocrinology
Last NameNair
First NameSreekumaran
EmailDasari.Surendra@mayo.edu
Submit Date2014-03-24
Num Groups1
Total Subjects7
Raw Data AvailableYes
Raw Data File Type(s)d
Uploaded File Size66 G
Analysis Type DetailLC-MS
Release Date2014-04-20
Release Version1
Sreekumaran Nair Sreekumaran Nair
https://dx.doi.org/10.21228/M8D59R
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000072 AN000073 AN000074 AN000075
Analysis type MS MS MS MS
Chromatography type Reversed phase HILIC Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type TOF TOF TOF TOF
MS instrument name Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units Raw MS Intensities Raw MS Intensities Raw MS Intensities Raw MS Intensities

MS:

MS ID:MS000053
Analysis ID:AN000072
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Positive-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000054
Analysis ID:AN000073
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Positive-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000055
Analysis ID:AN000074
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Negative-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE
  
MS ID:MS000056
Analysis ID:AN000075
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Negative-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50?1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and ~20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE