Summary of Study ST000046

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000045. The data can be accessed directly via it's Project DOI: 10.21228/M88G6G This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000046
Study TitleIdentification of altered metabolic pathways in Alzheimer's disease, mild cognitive impairment and cognitively normals using Metabolomics (plasma)
Study SummaryCriteria for the diagnosis of amnestic MCI included: (i) memory complaint documented by the patient and collateral source; (ii) impairment in 1 or more of the 4 cognitive domains (memory, executive functioning/attention, visuospatial, or language); (iii) essentially normal functional activities of daily living; and (iv) absence of dementia. In general, the amnestic MCI determination is made when the memory measures fall 1.0–1.5 SD below the means for age and education appropriate individuals in our community; however, rigid cutoffs on psychometric scores were not used to establish the diagnosis of amnestic MCI which was made on clinical grounds. The diagnosis of dementia was made using DSM-IV criteria, and the diagnosis of AD was made using established criteria. Subjects were considered to be CN if they performed within the normative range and did not meet criteria for MCI or dementia.
Institute
Mayo Clinic
DepartmentNeurology
Last NamePetersen
First NameRonald
EmailDasari.Surendra@mayo.edu
Submit Date2014-03-24
Num Groups1
Total Subjects15
Raw Data AvailableYes
Raw Data File Type(s)d
Uploaded File Size150 G
Analysis Type DetailLC-MS
Release Date2014-04-25
Release Version1
Ronald Petersen Ronald Petersen
https://dx.doi.org/10.21228/M88G6G
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000076 AN000077 AN000078 AN000079
Analysis type MS MS MS MS
Chromatography type Reversed phase HILIC Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um) Waters high-strength silica (150 x 2.1mm,1.8um) Waters ethylene-bridged hybrid (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type TOF TOF TOF TOF
MS instrument name Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF Agilent 6220 TOF
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units Raw MS Intensities Raw MS Intensities Raw MS Intensities Raw MS Intensities

MS:

MS ID:MS000057
Analysis ID:AN000076
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Positive-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000058
Analysis ID:AN000077
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Positive-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:POSITIVE
  
MS ID:MS000059
Analysis ID:AN000078
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Negative-ion mode/C18: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE
  
MS ID:MS000060
Analysis ID:AN000079
Instrument Name:Agilent 6220 TOF
Instrument Type:TOF
MS Type:ESI
MS Comments:Negative-ion mode/HILIC: A 6220 ToF MS (Agilent Technologies) was operated in both positive and negative electrospray ionization modes using a scan range of 50â??1,200 m/z. The mass accuracy and mass resolution were <5 parts per million (ppm) and â?¼20,000, respectively. The instrument settings were as follows: nebulizer gas temperature 325°C, capillary voltage 3.5 kV, capillary temperature 300°C, fragmentor voltage 150 V, skimmer voltage 58 V, octapole voltage 250 V, cycle time 0.5 s, and run time 15.0 min.
Ion Mode:NEGATIVE