Summary of Study ST000344

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000276. The data can be accessed directly via it's Project DOI: 10.21228/M83W3X This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000344
Study TitleEffects of dietary supplement on hamster metabolism
Study SummaryThis experiment aims to analyze spent media from a protein over-expression system. The treatment was a lipid supplement given to hamsters. The spent media was then analyzed to see how the lipid supplement affected lipid metabolism.
Institute
University of California, Davis
DepartmentGenome and Biomedical Sciences Facility
LaboratoryWCMC Metabolomics Core
Last NameFiehn
First NameOliver
Address1315 Genome and Biomedical Sciences Facility, 451 Health Sciences Drive, Davis, CA 95616
Emailofiehn@ucdavis.edu
Phone(530) 754-8258
Submit Date2016-02-09
Num Groups6
Total Subjects28
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2016-03-03
Release Version1
Oliver Fiehn Oliver Fiehn
https://dx.doi.org/10.21228/M83W3X
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000557 AN000558
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 6530 Agilent 6550
Column Waters Acquity CSH C18 (100 x 2.1mm,1.7um) Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units Peak height Peak height

MS:

MS ID:MS000493
Analysis ID:AN000557
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Lipidomics runs are MS1 data; Identifications made from pooled MS/MS runs
Ion Mode:POSITIVE
Capillary Voltage:3500
Collision Gas:Nitrogen
Dry Gas Flow:8 l/min
Dry Gas Temp:325
Fragment Voltage:120
Fragmentation Method:Auto MS/MS
Ion Source Temperature:325
Ion Spray Voltage:1000
Ionization:Pos
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 l/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65
  
MS ID:MS000494
Analysis ID:AN000558
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Lipidomics runs are performed in negative and positve mode (two filenames)
Ion Mode:NEGATIVE
Capillary Voltage:3500
Collision Gas:Nitrogen
Dry Gas Flow:13 l/min
Dry Gas Temp:200
Fragment Voltage:175
Fragmentation Method:Auto MS/MS
Ion Source Temperature:325
Ion Spray Voltage:1000
Ionization:Neg
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 l/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65
  logo