Summary of Study ST000413

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000322. The data can be accessed directly via it's Project DOI: 10.21228/M8V312 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000413
Study TitleMetabolic profiling during ex vivo machine perfusion of the human liver (part III)
Study SummaryAs donor organ shortages persist, functional machine perfusion is under investigation to improve preservation of the donor liver. The transplantation of donation after circulatory death (DCD) livers is limited by poor outcomes, but its application may be expanded by ex vivo repair and assessment of the organ before transplantation. Here we employed subnormothermic (21 °C) machine perfusion of discarded human livers combined with metabolomics to gain insight into metabolic recovery during machine perfusion. Improvements in energetic cofactors and redox shifts were observed, as well as reversal of ischemia-induced alterations in selected pathways, including lactate metabolism and increased TCA cycle intermediates. We next evaluated whether DCD livers with steatotic and severe ischemic injury could be discriminated from ‘transplantable’ DCD livers. Metabolomic profiling was able to cluster livers with similar metabolic patterns based on the degree of injury. Moreover, perfusion parameters combined with differences in metabolic factors suggest variable mechanisms that result in poor energy recovery in injured livers. We conclude that machine perfusion combined with metabolomics has significant potential as a clinical instrument for the assessment of preserved livers.
Institute
University of California, Davis
DepartmentGenome and Biomedical Sciences Facility
LaboratoryWCMC Metabolomics Core
Last NameFiehn
First NameOliver
Address1315 Genome and Biomedical Sciences Facility, 451 Health Sciences Drive, Davis, CA 95616
Emailofiehn@ucdavis.edu
Phone(530) 754-8258
Submit Date2016-07-01
Study CommentsThe first 4 samples were a test run to see how efficient the analysis was and were run on a lipidomics platform. The next 12 samples were the used in the paper and were the same as the original 4 samples, but they were split into 3 biological replicates and run on the GC platform.
Publicationsdoi:10.1038/srep22415
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2016-09-23
Release Version1
Oliver Fiehn Oliver Fiehn
https://dx.doi.org/10.21228/M8V312
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000653 AN000654
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 6530 Agilent 6550
Column Waters Acquity CSH C18 (100 x 2.1mm,1.7um) Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units counts counts

MS:

MS ID:MS000579
Analysis ID:AN000653
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
Capillary Voltage:3500 V
Collision Gas:Nitrogen
Dry Gas Flow:8 L/min
Dry Gas Temp:325 C
Fragment Voltage:120 V
Fragmentation Method:Auto MS/MS
Ion Source Temperature:325 C
Ion Spray Voltage:1000 V
Ionization:Pos
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 L/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750 V
Resolution Setting:extended dynamic range
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65 V
  
MS ID:MS000580
Analysis ID:AN000654
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:NEGATIVE
Capillary Voltage:3500 V
Collision Gas:Nitrogen
Dry Gas Flow:13 L/min
Dry Gas Temp:200 C
Fragment Voltage:175 V
Fragmentation Method:Auto MS/MS
Ion Source Temperature:325 C
Ion Spray Voltage:1000 V
Ionization:Neg
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 L/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750 V
Resolution Setting:extended dynamic range
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65 V