Summary of Study ST000457

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000353. The data can be accessed directly via it's Project DOI: 10.21228/M8DW3Q This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000457
Study TitleMetabolomics of Mice Cohousing and Microbiota Transfer
Study SummaryThe mice serum samples were extracted and prepared for a combined flow injection (FIA) and LC-MS/MS assay (Biocrates AbsoluteIDQ® p180 kit). The Biocrates AbsoluteIDQ® p180 kit (Biocrates Life Sciences AG, Innsbruck, Austria) can quantitatively measure ~188 biologically relevant metabolites from five analyte groups (acylcarnitines, amino acids, biogenic amines, glycerophospho- and sphingolipids, and hexoses) on a triple quadrupole mass spectrometer.
Institute
University of North Carolina
DepartmentDiscovery-Sciences-Technology (DST)
LaboratorySumner Lab
Last NameSumner
First NameSusan
AddressEastern Regional Comprehensive Metabolomics Resource Core, UNC Nutrition Research Institute, 500 Laureate Way, Kannapolis, NC, 28081
Emailsusan_sumner @unc.edu
Phone704-250-5066
Submit Date2016-09-01
Num Groups4
Total Subjects12
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2017-10-03
Release Version1
Susan Sumner Susan Sumner
https://dx.doi.org/10.21228/M8DW3Q
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000716 AN000717 AN000718
Analysis type MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase
Chromatography system Agilent 1100 Agilent 1100 Agilent 1100
Column Agilent Eclipse XDB-C18 (100 x 3.0mm,3.5um) Agilent Eclipse XDB-C18 (100 x 3.0mm,3.5um) Agilent Eclipse XDB-C18 (100 x 3.0mm,3.5um)
MS Type ESI ESI ESI
MS instrument type Triple quadrupole Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex API 4000 QTrap ABI Sciex API 4000 QTrap ABI Sciex API 4000 QTrap
Ion Mode POSITIVE POSITIVE NEGATIVE
Units Intensity Intensity Intensity

MS:

MS ID:MS000636
Analysis ID:AN000716
Instrument Name:ABI Sciex API 4000 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
Ion Mode:POSITIVE
  
MS ID:MS000637
Analysis ID:AN000717
Instrument Name:ABI Sciex API 4000 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
Ion Mode:POSITIVE
  
MS ID:MS000638
Analysis ID:AN000718
Instrument Name:ABI Sciex API 4000 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
Ion Mode:NEGATIVE
  logo