Summary of Study ST000903

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000627. The data can be accessed directly via it's Project DOI: 10.21228/M8MT2H This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)
Study IDST000903
Study TitlePharmacometabolomic analysis of rat hippocampus and plasma in response to chronic stress and albiflorin treament
Study TypeAnimal study
Study SummaryMale Sprague-Dawley (SD) rats were exposed to one random stressor per day for 35 d. Following four weeks of stress exposure, rats with stress-induced depression-like behaviors were treated daily with either saline, fluoxetine or albiflorin for 7 days via intragastric gavage. Rat heparinized plasma was collected after drug treatment. After behavior tests, rats were sacrificed and the hippocampus was collected. Pharmacometabolomic analysis was conducted for both plasma and hippocampal samples
Institute
Beijing Wonner Biotech. Ltd. Co.
Last NameZhang
First NameZuoguang
AddressNo.9, Kexing Road, Fengtai, Beijing, Beijing, 101111, China
Emailleekefeng@hotmail.com
Phone86-10-65670787
Submit Date2017-11-16
Num Groups4
Study CommentsAnimal study
Analysis Type DetailLC-MS
Release Date2018-02-07
Release Version1
Zuoguang Zhang Zuoguang Zhang
https://dx.doi.org/10.21228/M8MT2H
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001469 AN001470
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Waters ACQUITY UPLC Waters ACQUITY UPLC
Column Luna NH2 aminopropyl HPLC Luna NH2 aminopropyl HPLC
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex 6500 QTrap ABI Sciex 6500 QTrap
Ion Mode NEGATIVE POSITIVE
Units AUC AUC

MS:

MS ID:MS001357
Analysis ID:AN001469
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
Ion Mode:NEGATIVE
Collision Energy:Compound dependent
Collision Gas:25
Mass Accuracy:0.1 Da
Source Temperature:475 ºC
Spray Voltage:-4500 ºC
  
MS ID:MS001358
Analysis ID:AN001470
Instrument Name:ABI Sciex 6500 QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
Ion Mode:POSITIVE
Collision Energy:Compound dependent
Collision Gas:25
Mass Accuracy:0.1 Da
Source Temperature:475 ºC
Spray Voltage:5500 ºC
  logo