Summary of Study ST001167

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000779. The data can be accessed directly via it's Project DOI: 10.21228/M8097N This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001167
Study TitleComprehensive Profiling by Non-targeted Stable Isotope Tracing Capillary Electrophoresis-Mass Spectrometry
Study SummaryWe developed a stable-isotope tracing capillary electrophoresis (CE)-MS metabolomics approach to cover polar metabolites as well as isotopologues in a non-targeted way. An in-house developed software enables high throughput processing of complex multi-dimensional data. The practicability is demonstrated analysing 13C-U-glucose exposed prostate cancer and non-cancer cells.
Institute
Dalian Institute Of Chemical Physics
Last NameWang
First NameZhichao
Address457, Zhongshan Road
Emailwangzc05@dicp.ac.cn
Phone+86-15998625250
Submit Date2019-01-06
Study CommentsComprehensive Profiling by Non-targeted Stable Isotope Tracing Capillary Electrophoresis-Mass Spectrometry - A Novel Tool Complementing Metabolomics Analyses of Polar Metabolites
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2020-01-06
Release Version1
Zhichao Wang Zhichao Wang
https://dx.doi.org/10.21228/M8097N
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001929 AN001930
Analysis type MS MS
Chromatography type CE CE
Chromatography system Agilent 1290 Infinity II Agilent 1290 Infinity II
Column a fused silica capillary (50 μm i.d. × 80 cm) a fused silica capillary (50 μm i.d. × 80 cm)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name Agilent 6224 TOF Agilent 6224 TOF
Ion Mode POSITIVE NEGATIVE
Units Relative intensity after normalization Relative intensity after normalization

MS:

MS ID:MS001785
Analysis ID:AN001929
Instrument Name:Agilent 6224 TOF
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:nebulizer pressure of 5 psig, dry gas temperature of 300 °C, nitrogen flow of 7 L/min, capillary voltage of 4 kV, fragmentor of 105 V, skimmer of 50 V, Oct RFV of 650 V, acquisition rate of 1.5 spectra/s and mass range of 60-1,000 were utilized.
Ion Mode:POSITIVE
  
MS ID:MS001786
Analysis ID:AN001930
Instrument Name:Agilent 6224 TOF
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:capillary voltage of 3.5 kV, fragmentor of 125 V and mass range of 50-1,000 were set in the TOF/MS analysis. During sample analysis, reference masses were applied to ensure the real-time calibration of exact mass measurement.
Ion Mode:NEGATIVE