Summary of Study ST001242

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000830. The data can be accessed directly via it's Project DOI: 10.21228/M8D68Q This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001242
Study TitleGlobal Metabolic Analysis Trisomy 21 - Cohort 3, CSF
Study Summaryglobal metabolic analysis of CSF from individuals with and without trisomy 21.
Institute
University of Colorado Denver
Last NameCulp-Hill
First NameRachel
Address12801 E 17th Ave L18-9403D, Aurora, Colorado, 80045, USA
Emailrachel.hill@cuanschutz.edu
Phone303-724-5798
Submit Date2019-08-13
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2019-08-21
Release Version1
Rachel Culp-Hill Rachel Culp-Hill
https://dx.doi.org/10.21228/M8D68Q
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002063 AN002064
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) Phenomenex Kinetex C18 (150 x 2.1mm,2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units relative abundance relative abundance

MS:

MS ID:MS001914
Analysis ID:AN002063
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive mass spectrometer (Thermo Fisher Scientific, San Jose, CA, USA) was operated in positive ion mode using electrospray ionization, scanning in Full MS mode (1μscan) from 65 to 975 m/z at 70,000 resolution, with 4 kV spray voltage, 45 sheath gas, 15 auxiliary gas. MS analysis and data elaboration were performed as described74,75. Calibration was performed prior to analysis using the PierceTM Positive Ion Calibration Solution (Thermo Fisher Scientific).
Ion Mode:POSITIVE
  
MS ID:MS001915
Analysis ID:AN002064
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive mass spectrometer (Thermo Fisher Scientific, San Jose, CA, USA) was operated in negative ion mode using electrospray ionization, scanning in Full MS mode (1μscan) from 65 to 975 m/z at 70,000 resolution, with 4 kV spray voltage, 45 sheath gas, 15 auxiliary gas. MS analysis and data elaboration were performed as described74,75. Calibration was performed prior to analysis using the PierceTM Negative Ion Calibration Solution (Thermo Fisher Scientific).
Ion Mode:NEGATIVE