Summary of Study ST001331

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000909. The data can be accessed directly via it's Project DOI: 10.21228/M8668V This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001331
Study TitleMulti-omics of OsGF14b-mediated innate immunity against panicle blast in rice (part-II)
Study SummaryIn the present study, we used a multi-omics approach to decipher the molecular mechanisms of OsGF14b in governing panicle resistance to Magnaporthe oryzae.Results revealed OsGF14b mediated panicle blast resistance was involved in the activation of auxin and JA signaling pathways, resulting in reprogramming of the phenylpropanoid and diterpenoid pathway.
Institute
Agro-biological Gene Research Center , Guangdong Academy of Agricultural Sciences
Last NameYan
First NameShijuan
AddressNo. 20 Jinying Road, Tianhe District, Guangzhou City, Guangdong Province, 510640, China.
Emailshijuan@agrogene.ac.cn
Phone+86-020-38213643
Submit Date2020-03-13
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2020-12-31
Release Version1
Shijuan Yan Shijuan Yan
https://dx.doi.org/10.21228/M8668V
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002219 AN002220
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters CORTECS C18 (150 x 2.1mm,2.7um) Waters CORTECS C18 (150 x 2.1mm,2.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Fusion Tribrid Orbitrap Thermo Fusion Tribrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Relative content Relative content

MS:

MS ID:MS002065
Analysis ID:AN002219
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The spray voltage was set to 3500 V in the positive-ion modes, with the following ion-source properties: sheath gas, 45 Arbs; auxiliary gas, 10 Arbs; sweep gas, 0 Arbs; ion-transfer tube temperature, 320 °C; vaporizer temp, 350 °C. All FTMS data were acquired using the following conditions: detector type, orbitrap; orbitrap resolution, 120000; scan range was set to m/z 200-1200. The AGC was set at 5.0 e5 and the maximum injection time was set to 100 ms. RF lens was set to 60%, and the microscans was 1. data type, profile. All FTMS2 data were acquired using the following conditions: isolation mode, quadrupole; isolation window, 1 m/z; detector type, orbitrap; scan range, auto; AGC target, 5.0 e4; maximum injection time, 100 ms; microscans, 1; orbitrap resolution, 30000; first mass, 50 m/z; data type, profile. The HCD collision energy was set to 25% with ± HCD collision energy was set 5% in positive mode, and the HCD collision energy was set to 30% with ± HCD collision energy was set 5% in negative mode. All data was acquired by the Xcalibur 4.1 software (Thermo Fisher Scientific, USA). Thermo Scientific™ LipidSearch™ 5.0 software was used for lipidome data processing.
Ion Mode:POSITIVE
  
MS ID:MS002066
Analysis ID:AN002220
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The spray voltage was set to -3000 V in the negative-ion modes, with the following ion-source properties: sheath gas, 45 Arbs; auxiliary gas, 10 Arbs; sweep gas, 0 Arbs; ion-transfer tube temperature, 320 °C; vaporizer temp, 350 °C. All FTMS data were acquired using the following conditions: detector type, orbitrap; orbitrap resolution, 120000; scan range was set to m/z 200-1200. The AGC was set at 5.0 e5 and the maximum injection time was set to 100 ms. RF lens was set to 60%, and the microscans was 1. data type, profile. All FTMS2 data were acquired using the following conditions: isolation mode, quadrupole; isolation window, 1 m/z; detector type, orbitrap; scan range, auto; AGC target, 5.0 e4; maximum injection time, 100 ms; microscans, 1; orbitrap resolution, 30000; first mass, 50 m/z; data type, profile. The HCD collision energy was set to 25% with ± HCD collision energy was set 5% in positive mode, and the HCD collision energy was set to 30% with ± HCD collision energy was set 5% in negative mode. All data was acquired by the Xcalibur 4.1 software (Thermo Fisher Scientific, USA). Thermo Scientific™ LipidSearch™ 5.0 software was used for lipidome data processing.
Ion Mode:NEGATIVE
  logo