This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001022. The data can be accessed directly via it's Project DOI: 10.21228/M8KT26 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)
Study IDST001515
Study TitleA Metabolomic Signature of Glucagon Action in Healthy Individuals with Overweight/Obesity Humans
Study SummaryObjective: We sought to identify the circulating metabolites that would serve as markers of glucagon action. Design: In this study, we performed a continuous 72-hour glucagon infusion in healthy individuals with overweight/obesity. Participants were randomized to either glucagon (12.5 ng/kg/min) (GCG 12.5) or glucagon (25 ng/kg/min) GCG 25 or a placebo control were included. A comprehensive metabolomics analysis was then performed from plasma isolated at several time points during the infusion to identify markers of glucagon activity.
Institute
Translational Research Institute- AdventHealth Orlando
Last NameWhytock
First NameKatie
Address301 E Princeton St, Orlando, FL, 32804
EmailKatie.Whytock@adventhealth.com
Phone321-945-9982
Submit Date2020-10-26
Num Groups3
Total Subjects33
Raw Data AvailableYes
Analysis Type DetailLC-MS
Release Date2020-12-01
Release Version1
Katie Whytock Katie Whytock
https://dx.doi.org/10.21228/M8KT26
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002511 AN002512 AN002513 AN002514
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units scaled units scaled units scaled units scaled units

MS:

MS ID:MS002329
Analysis ID:AN002511
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:POSITIVE
  
MS ID:MS002330
Analysis ID:AN002512
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:POSITIVE
  
MS ID:MS002331
Analysis ID:AN002513
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:NEGATIVE
  
MS ID:MS002332
Analysis ID:AN002514
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Proprietary analytical software for integration and peak picking
Ion Mode:NEGATIVE