Summary of Study ST001606

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001031. The data can be accessed directly via it's Project DOI: 10.21228/M8F39C This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001606
Study TitleAromatic amino acid metabolism by the anaerobic gut bacterium Clostridium sporogenes
Study SummaryGerm-free mice were mono-colonized with wild-type Clostridium sporogenes or its isogenic phenyllactate dehydratase (fldC) mutant. Feces, cecal contents, serum, and urine were collected for untargeted GC-TOF analysis.
Institute
Stanford University
LaboratoryDodd
Last NamePruss
First NameKali
Address300 Pasteur Drive, Lane 235
Emailkmpruss@stanford.edu
Phone6507212961
Submit Date2020-11-20
Raw Data AvailableYes
Raw Data File Type(s)cdf
Analysis Type DetailGC-MS
Release Date2020-12-01
Release Version1
Kali Pruss Kali Pruss
https://dx.doi.org/10.21228/M8F39C
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002639
Analysis type MS
Chromatography type GC
Chromatography system Agilent 6890 GC
Column Restek Rtx-5Sil (30m x 0.25mm,0.25m)
MS Type EI
MS instrument type GC-TOF
MS instrument name Leco Pegasus IV TOF
Ion Mode POSITIVE
Units peak area

MS:

MS ID:MS002451
Analysis ID:AN002639
Instrument Name:Leco Pegasus IV TOF
Instrument Type:GC-TOF
MS Type:EI
MS Comments:A Leco Pegasus IV time of flight mass spectrometer is controlled by the Leco ChromaTOF software vs. 2.32 (St. Joseph, MI). The transfer line temperature between gas chromatograph and mass spectrometer is set to 280°C. Electron impact ionization at 70V is employed with an ion source temperature of 250°C. Acquisition rate is 17 spectra/second, with a scan mass range of 85-500 Da. Data processing: Peaks reported are normalized to average mtic for each treatment. The algorithm used was developed to replace missing values, assuming each study investigates a specific organ. When very different organs (like in this study) are tested, a compound that is found in one organ but not in others would still be yielding data through noise replacements, or sometimes by adjacent compounds. We therefore report % of positive detections for all compounds in each organ.
Ion Mode:POSITIVE
  logo