Summary of Study ST002028
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001287. The data can be accessed directly via it's Project DOI: 10.21228/M8BX22 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002028 |
Study Title | Metabolomics Analysis of Blood Plasma and Stool from Six Week Flaxseed Dietary Intervention in Postmenopausal Women (Stool/HILIC) |
Study Summary | : Samples were taken before and after 6 weeks of flaxseed dietary intervention. Serum and fecal metabolomics were performed to characterize the metabolomic profiles of serum and stool metabolites pre- and post-intervention. |
Institute | University of California, Davis |
Last Name | folz |
First Name | jake |
Address | 451 Health Science Drive |
jfolz@ucdavis.edu | |
Phone | 7155636311 |
Submit Date | 2021-12-21 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2023-01-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003298 |
---|---|
Analysis type | MS |
Chromatography type | HILIC |
Chromatography system | Vanquish |
Column | Waters Acquity UPLC BEH amide,(150 x 2.1mm,1.7um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE |
Units | normalized peak height |
MS:
MS ID: | MS003068 |
Analysis ID: | AN003298 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | A Thermo Q-Exactive HF Orbitrap MS instrument was operated in positive and negative ESI mdoes respectively with the following parameters: mass range 60−900 m/z; spray voltage 3.6kV (ESI+) and −3kV (ESI−), sheath gas (nitrogen) flow rate 60 units; auxiliary gas (nitrogen) flow rate 25 units, capillary temperature 320 ◦C, full scan MS1 mass resolving power 60,000, data-dependent MSMS (dd-MSMS) 4 scans per cycle, normalized collision energy at 20%, 30%, and 40%, dd-MSMS mass resolving power 15,000. Thermo Xcalibur 4.0.27.19 was used for data acquisition and analysis. Instruments was tuned and calibrated by manufacturer’s recommendations. |
Ion Mode: | POSITIVE |