Summary of Study ST002231

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001421. The data can be accessed directly via it's Project DOI: 10.21228/M81X41 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002231
Study TitleMetabolomics Analysis of HOG-EV and HOG-R132H Cells with and without BAY 2402234 Treatment
Study TypeMetabolomics Analysis
Study SummaryHOG cells were plated in 6-well plates (0.5 × 10^6 cells per well). 24 hours later, HOG-EV or HOG-R132H cells were treated for 24 hours with 10 nM BAY 2402234 or DMSO. Cells were then harvested for LC-MS analysis.
Institute
UT Southwestern Medical Center
DepartmentChildren's Research Institute
LaboratoryMcBrayer Laboratory
Last NameMcBrayer
First NameSamuel
Address6000 Harry Hines Boulevard, NL10.110K, Dallas, TX 75235, USA
Emailsamuel.mcbrayer@utsouthwestern.edu
Phone(214)-648-3730
Submit Date2022-07-14
Num Groups4
Total Subjects1
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2022-07-28
Release Version1
Samuel McBrayer Samuel McBrayer
https://dx.doi.org/10.21228/M81X41
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003640 AN003641
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Vanquish Flex UHPLC Vanquish Flex UHPLC
Column Millipore ZIC-pHILIC Millipore ZIC-pHILIC
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF-X Orbitrap Thermo Q Exactive HF-X Orbitrap
Ion Mode POSITIVE NEGATIVE
Units TIC-Corrected Peak Area TIC-Corrected Peak Area

MS:

MS ID:MS003391
Analysis ID:AN003640
Instrument Name:Thermo Q Exactive HF-X Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Spectra were acquired with a resolving power of 60,000 full width at half maximum (FWHM), a scan range set to 80–1,200 m/z, and polarity switching. Data-dependent MS/MS data was acquired on unlabeled pooled samples to confirm metabolite IDs when necessary. Peaks were integrated using El-Maven 0.12.0 software (Elucidata) or TraceFinder 5.1 SP2 software (Thermo Fisher). Total ion counts were quantified using Freestyle 1.7 SP1 software (Thermo Fisher). Peaks were normalized to total ion counts using the R statistical programming language.
Ion Mode:POSITIVE
  
MS ID:MS003392
Analysis ID:AN003641
Instrument Name:Thermo Q Exactive HF-X Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Spectra were acquired with a resolving power of 60,000 full width at half maximum (FWHM), a scan range set to 80–1,200 m/z, and polarity switching. Data-dependent MS/MS data was acquired on unlabeled pooled samples to confirm metabolite IDs when necessary. Peaks were integrated using El-Maven 0.12.0 software (Elucidata) or TraceFinder 5.1 SP2 software (Thermo Fisher). Total ion counts were quantified using Freestyle 1.7 SP1 software (Thermo Fisher). Peaks were normalized to total ion counts using the R statistical programming language.
Ion Mode:NEGATIVE