Summary of Study ST002282

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001462. The data can be accessed directly via it's Project DOI: 10.21228/M8R997 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002282
Study TitleDetection of Methyl jasmonate (MeJA) in Plant root VOCs
Study SummaryMethyl jasmonate (MeJA) is a well-known plant hormone known for plant defense and plant-plant signaling. However, most of the studies are focussed on its aboveground presence and functions. Here we report that MeJA is also released by plant roots in a volatile form. More importantly, it is shown in Arabidopsis growing in natural conditions in soil.
Institute
National University of Singapore
Last NameKulkarni
First NameOmkar
AddressDept of Biological Sciences,Metabolites Biology Lab,, Science drive 4,Block S1A #06-03
Emailkomkar21@gmail.com
Phone98668733
Submit Date2022-08-25
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2022-11-25
Release Version1
Omkar Kulkarni Omkar Kulkarni
https://dx.doi.org/10.21228/M8R997
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003727
Analysis type MS
Chromatography type GC
Chromatography system Agilent 7890B
Column Agilent DB-FFAP
MS Type EI
MS instrument type Single quadrupole
MS instrument name Agilent 5977B
Ion Mode UNSPECIFIED
Units ion intensity peak area

MS:

MS ID:MS003475
Analysis ID:AN003727
Instrument Name:Agilent 5977B
Instrument Type:Single quadrupole
MS Type:EI
MS Comments:The mass spectrometer was in electron ionization mode with an ionization energy of 70 eV, scan range of 40-300 m/z and solvent delay of 3.75 minutes. Analysis was performed in single ion monitoring (SIM) mode by monitoring the ions at 83, 151.1, and 224.1 with a dwell time of 150 ms. Mass Hunter Qualitative Analysis was used to extract and integrate peak spectra. The peak area of these ions was considered for the relative quantification of MeJA among different samples.
Ion Mode:UNSPECIFIED
  logo