Summary of Study ST002956

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001839. The data can be accessed directly via it's Project DOI: 10.21228/M80T6F This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002956
Study TitleAutomated preparation of plasma lipids, metabolites, and proteins for LC/MS-based analysis of a high-fat diet in mice
Study TypeMethod Development
Study SummaryWe designed an automated liquid-liquid extraction method with minimal contamination and human intervention. This approach enables accurate and precise collection of metabolite, lipid fractions, and protein pellet from a small volume of mice plasma for multiomic analysis.
Institute
Calico Life Sciences
DepartmentDepartment of Mass Spectrometry-Technology Lab
LaboratoryMetabolomics Lab
Last NameVu
First NameNgoc
Address1130 Veterans BLVD
Emailngoc@calicolabs.com
Phone6504205430
Submit Date2023-07-06
Num Groups3
Total Subjects90
Num Males90
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2024-07-29
Release Version1
Ngoc Vu Ngoc Vu
https://dx.doi.org/10.21228/M80T6F
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004853 AN004854 AN004855 AN004856
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC Ion pair
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Thermo Accucore C30 column (250 x 2.1 mm, 2.6 µm) Thermo Accucore C30 column (250 x 2.1 mm, 2.6 µm) SeQuant ZIC- pHILIC (150 x 2.1mm,5um) Agilent Zorbax Extend C18 column (150 x 2.1 mm, 1.8 µm)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Log2(Top Peak Area) Log2(Top Peak Area) Log2(Top Peak Area) Log2(Top Peak Area)

MS:

MS ID:MS004598
Analysis ID:AN004853
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Set parameters on MS1 were 140,000 resolution, AGC target of 3e6 at max. IT of 100 ms with scan range of 200 to 2000 m/z. MS2 parameters consisted of 17,500 resolution at loop count 8, an AGC target of 3e6 at max. IT of 150 ms with isolation window set to 1 m/z and underfill ratio at 1%. Dynamic exclusion was set at 15 sec with an apex trigger from 5 to 30 sec. Stepped collision energies were set to 20, 30 and 40% NCE. Raw files were converted to mzML using MsConverter, and search against in-house libraries for feature identification using Maven 2.
Ion Mode:POSITIVE
  
MS ID:MS004599
Analysis ID:AN004854
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Set parameters on MS1 were 140,000 resolution, AGC target of 3e6 at max. IT of 100 ms with scan range of 200 to 2000 m/z. MS2 parameters consisted of 17,500 resolution at loop count 8, an AGC target of 3e6 at max. IT of 150 ms with isolation window set to 1 m/z and underfill ratio at 1%. Dynamic exclusion was set at 15 sec with an apex trigger from 5 to 30 sec. Stepped collision energies were set to 20, 30 and 40% NCE. Raw files were converted to mzML using MsConverter, and search against in-house libraries for feature identification using Maven 2.
Ion Mode:NEGATIVE
  
MS ID:MS004600
Analysis ID:AN004855
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The mass spectrometer was operated in positive ion mode using data-dependent acquisition (DDA) mode with the following parameters: resolution = 70,000, AGC target = 3.00E + 06, maximum IT (ms) = 100, scan range = 70–1050. The MS2 parameters were as follows: resolution = 17,500, AGC target = 1.00E + 05, maximum IT (ms) = 50, loop count = 6, isolation window (m/z) = 1, (N)CE = 20, 40, 80; underfill ratio = 1.00%, Apex trigger(s) = 3–10, dynamic exclusion(s) = 25
Ion Mode:POSITIVE
  
MS ID:MS004601
Analysis ID:AN004856
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The mass spectrometer was operated in negative ion mode using data-dependent acquisition (DDA) mode with the following parameters: resolution = 70,000, AGC target = 1.00E + 06, maximum IT (ms) = 100, scan range = 70–1050. The MS2 parameters were as follows: resolution = 17,500, AGC target = 1.00E + 05, maximum IT (ms) = 50, loop count = 6, isolation window (m/z) = 1, (N)CE = 20, 50, 100; underfill ratio = 1.0 0%, Apex trigger(s) = 3–12, dynamic exclusion(s) = 20
Ion Mode:NEGATIVE