Summary of Study ST003307
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002057. The data can be accessed directly via it's Project DOI: 10.21228/M8QN7M This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST003307 |
Study Title | Untargeted metabolomics of rhizosphere soil from 4-years Panax ginseng that was treated with endo-borneol under field condition |
Study Summary | To study the rhizosphere soil matabolism of 4-years Panax ginseng that were leaf-sprayed with endo-borneol at different concentrations (0, 0.1 mg/L, and 100 mg/L) under field condition, liquid chromarography tandem mass spectrometry was used for examination. Each treatment is set with 6 replicates for assessing nontargeted metabolomics. The LC-MS/MS analysis was performed using a Thermo UHPLC-Q Exactive HF-X system equipped with an ACQUITY HSS T3 column. As a result, a total of 296 and 569 metabolites were identified in negative ion mode and positive mode, respectively. |
Institute | Yunnan University |
Department | School of Agriculture |
Laboratory | Key Laboratory of Agro-Biodiversity and Pest Management of Education Ministry of China |
Last Name | Xing-Yu |
First Name | Ji |
Address | Road Fengyuan, District Panlong, Kunming, Yunnan, China |
xingyu.ji@hotmail.com | |
Phone | +86-13354989110 |
Submit Date | 2024-06-03 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2024-07-15 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005418 | AN005419 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish Horizon | Thermo Vanquish Horizon |
Column | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF-X Orbitrap | Thermo Q Exactive HF-X Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak area | Peak area |
MS:
MS ID: | MS005144 |
Analysis ID: | AN005418 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Full MS resolution was 60000, and MS/MS resolution was 7500. Data acquisition was performed with the Data Dependent Acquisition (DDA) mode. The detection was carried out over a mass range of 70-1050 m/z. |
Ion Mode: | POSITIVE |
MS ID: | MS005145 |
Analysis ID: | AN005419 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Full MS resolution was 60000, and MS/MS resolution was 7500. Data acquisition was performed with the Data Dependent Acquisition (DDA) mode. The detection was carried out over a mass range of 70-1050 m/z. |
Ion Mode: | NEGATIVE |