Summary of Study ST003328

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002070. The data can be accessed directly via it's Project DOI: 10.21228/M81Z4C This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003328
Study TitleIncreased Cholesterol Synthesis Drives Neurotoxicity in Patient Stem Cell-Derived Model of Multiple Sclerosis - cellular lipidomics
Study SummaryLipidomics analysis was performed on directly induced neural stem/progenitor cell (iNSC) lines derived from fibroblasts of patients with progressive multiple sclerosis (PMS) versus age matched controls (AMC) treated or untreated with cholesterol synthesis inhibitor simvastatin.
Institute
University of Colorado Denver
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2024-07-17
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-08-08
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M81Z4C
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005452 AN005453
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (30 x 2.1mm,1.7um) Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE
Units peak area peak area

MS:

MS ID:MS005178
Analysis ID:AN005452
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive was run independently in positive and negative ion mode, scanning using full MS from 125-1500 m/z at 70,000 resolution and top 10 data-dependent MS2 at 17,500 resolution. Electrospray ionization was achieved with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. Calibration was performed prior to the run using the PierceTM Positive and Negative Ion Calibration Solutions (Thermo Fisher Scientific). Run order of samples was randomized and technical replicates were injected after every 4 samples to assess quality control.
Ion Mode:NEGATIVE
  
MS ID:MS005179
Analysis ID:AN005453
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive was run independently in positive and negative ion mode, scanning using full MS from 125-1500 m/z at 70,000 resolution and top 10 data-dependent MS2 at 17,500 resolution. Electrospray ionization was achieved with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. Calibration was performed prior to the run using the PierceTM Positive and Negative Ion Calibration Solutions (Thermo Fisher Scientific). Run order of samples was randomized and technical replicates were injected after every 4 samples to assess quality control.
Ion Mode:POSITIVE