Summary of Study ST003532

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002173. The data can be accessed directly via it's Project DOI: 10.21228/M8R23J This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003532
Study TitleMicropeptide hSPAR, a glutamine regulator, suppresses tumor growth via TRIM21-P27KIP1-mTOR pathway - HEK293T human embryonic kidney cells
Study SummaryThe microprotein hSPAR can specifically regulate the mTOR signaling activity and cell proliferation in breast cancer cells. However, such regulatory effects of hSPAR are not applicable in HEK293T cells. Metabolic data of amino acids indicate that overexpressing hSPAR does not affect the content of amino acids in HEK293T cells, including glutamine. The metabolic variations in amino acids triggered by hSPAR in different cell types may be the underlying molecular mechanism for the distinct regulatory effects of hSPAR.
Institute
University Of Science And Technology of China
Last NameWang
First NameWei
Address443 Huangshan Road, Hefei city, Anhui Province, 230022, China
EmailWW571@mail.ustc.edu.cn
Phone18604523231
Submit Date2024-10-10
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2025-01-06
Release Version1
Wei Wang Wei Wang
https://dx.doi.org/10.21228/M8R23J
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005802 AN005803
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system SCIEX ExionLC AD SCIEX ExionLC AD
Column Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTRAP QTRAP
MS instrument name ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap
Ion Mode POSITIVE NEGATIVE
Units ng/mg of cells ng/mg of cells

MS:

MS ID:MS005522
Analysis ID:AN005802
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:-
Ion Mode:POSITIVE
Analysis Protocol File:USTC_Protocol.pdf
  
MS ID:MS005523
Analysis ID:AN005803
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:-
Ion Mode:NEGATIVE
Analysis Protocol File:USTC_Protocol.pdf
  logo