Summary of Study ST001108

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000740. The data can be accessed directly via it's Project DOI: 10.21228/M81D57 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001108
Study TitleNMR Metabolomics of Newborn Heart Tissue Exposed to Excess Maternal Cortisol in Late Gestation - Fetal (part -III)
Study TypeComparison
Study SummarySerum from mothers and fetuses exposed to excess maternal cortisol in late gestation and untreated was compared via NMR metabolomic analysis
Institute
University of Florida
DepartmentBiochemsitry & Molecular Biology
Last NameWalejko
First NameJacquelyn
AddressR3-226 Academic Research Building, Department of Biochemistry and Molecular Biology, PO Box 100245, Gainesville, FL 32610-0245
Emailjwalejko@uga.edu
PhoneNA
Submit Date2018-12-04
Num Groups2
Total Subjects36
Raw Data AvailableYes
Raw Data File Type(s)fid
Analysis Type DetailNMR
Release Date2019-03-06
Release Version1
Jacquelyn Walejko Jacquelyn Walejko
https://dx.doi.org/10.21228/M81D57
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


NMR:

NMR ID:NM000138
Analysis ID:AN001802
Instrument Name:Bruker Avance III
Instrument Type:FT-NMR
NMR Experiment Type:1D 1H
Field Frequency Lock:H2O+D2O
Spectrometer Frequency:600 MHz
NMR Probe:5mm Cryoprobe
NMR Solvent:D2O
NMR Tube Size:5mm
Shimming Method:Topshim
Pulse Sequence:cpmgpr1d
Water Suppression:Presaturation
Power Level:7.37 W
Receiver Gain:64
Offset Frequency:2824.2
Presaturation Power Level:6.41E-05
Temperature:4C
Number Of Scans:128
Dummy Scans:16
Acquisition Time:1.8173
Relaxation Delay:4 sec
Spectral Width:15.0182 ppm
Num Data Points Acquired:32764
Real Data Points:65536
Line Broadening:1
  logo