Summary of Study ST001389

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000952. The data can be accessed directly via it's Project DOI: 10.21228/M8N397 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001389
Study TitleQuantitative amino acids and biogenic amines study on total murine liver tissue from mice at different age
Study TypeLiver tissue/Primary tissue
Study SummaryAmino acids and biogenic amines in total liver tissue from healthy C57BL/6 mice at 1, 7, 14, 21, 28 and 56 day after birth was analyzed.
Institute
Helmholtz Centre for Environmental Research
DepartmentDepartment of Molecular Systems biology
LaboratoryFunctional Metabolomics
Last NameRolle-Kampczyk
First NameUlrike
AddressPermoserstrasse 15, 04318 Leipzig, Germany
Emailulrike.rolle-kampczyk@ufz.de
Phone0049 341 235 1537
Submit Date2020-06-02
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2020-06-10
Release Version1
Ulrike Rolle-Kampczyk Ulrike Rolle-Kampczyk
https://dx.doi.org/10.21228/M8N397
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Sample Preparation:

Sampleprep ID:SP001471
Sampleprep Summary:Solvents: Acetonitril (Merck KGaA, Darmstadt, Germany hypergrade for LC-MS) Water MiliQ, Extracting agent - ACN / H2O (1:1) Equipment 4 steel balls size M Eppendorf Tubes 2mL Tissue slicer (Rettberg, Germany) Centrifuge (Sigma) Work steps To approximately 100 mg of sample four steel balls of size M rae added in Eppendorf tubes. Then add for each mg of sample 5 µL of extracting agent. Shake the samples for 10 minutes at 30 Hz in the tissue slicer and centrifuge for 2 minutes at 14000 rpm. The supernatant is used for targeted analytics as described in the kit manufactures manual. Kit measurement The analysis was performed using the validated Bile Acid Kit (Biocrates Life Sciences, Inssbruck, Austria) as described in Pham et al. 2017 [1]. Data processing is carried out with the provided quantitation method Kit (Biocrates Life Sciences AG, Innsbruck, Austria). 1 Pham HT, Arnhard K, Asad YJ, Deng L, Felder TK, St John-Williams L, et al. Inter-Laboratory Robustness of Next-Generation Bile Acid Study in Mice and Humans: International Ring Trial Involving 12 Laboratories. The Journal of Applied Laboratory Medicine 2019;1:129-42.
Sampleprep Protocol Filename:sven_haange_20200602_Sample_preparation.pdf
  logo