Summary of Study ST001978

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001255. The data can be accessed directly via it's Project DOI: 10.21228/M8GT41 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001978
Study TitleAnti-oxidation metabolism measurement in mammalian cells and tissues by quantitative LC/MS method (V)
Study SummaryAnti-oxidation metabolism measurement in human patient CSF by quantitative LC/MS method.
Institute
Boston Children's Hospital, Harvard Medical School
Last NamePetrova
First NameBoryana
Address300 Longwood Ave
Emailboryana.petrova@childrens.harvard.edu
Phone6173557433
Submit Date2021-09-15
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2022-08-29
Release Version1
Boryana Petrova Boryana Petrova
https://dx.doi.org/10.21228/M8GT41
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Sample Preparation:

Sampleprep ID:SP002064
Sampleprep Summary:CSF injected into a ZIC-pHILIC 150 × 2.1 mm (5 µm particle size) column (EMD Millipore) operated on a Dionex UltiMate 3000 UPLC system (Thermo Fisher Scientific). Chromatographic separation was achieved using the following conditions: buffer A was acetonitrile; buffer B was 20 mM ammonium carbonate, 0.1% ammonium hydroxide. Gradient conditions were: linear gradient from 20% to 80% B; 20–20.5 min: from 80% to 20% B; 20.5–28 min: hold at 20% B. The column oven and autosampler tray were held at 25 °C and 4 °C, respectively. The MS data acquisition was on a QExactive benchtop orbitrap mass spectrometer equipped with an Ion Max source and a HESI II probe and was performed in a range of m/z= 70–1000, with the resolution set at 70,000, the AGC target at 1x106, and the maximum injection time (Max IT) at 20 msec. For tSIM scans, the resolution was set at 70,000, the AGC target was 1x105, and the max IT was 100 msec. Relative quantitation of polar metabolites was performed with TraceFinder 4.1 (Thermo Fisher Scientific) using a 5 ppm mass tolerance and referencing an in-house library of chemical standards. Pooled samples and fractional dilutions were prepared as quality controls and only those metabolites were taken for further analysis, for which the correlation between the dilution factor and the peak area was >0.95 (high confidence metabolites). Normalization for biological material amounts was based on the total integrated peak area values of high-confidence metabolites within an experimental batch after normalizing to the averaged factor from all mean-centered chromatographic peak areas of isotopically labeled amino acids internal standards (Cambridge Isotope Laboratories). The data were Log transformed and Pareto scaled for MetaboAnalyst-based statistical or pathway analysis (41). We profiled 200 metabolites, 85 of which were detected in CSF and passed our quality control protocol.