Summary of Study ST002197

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001400. The data can be accessed directly via it's Project DOI: 10.21228/M8RM5T This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002197
Study TitleMetabolic signature of C-protein induced myositis mouse model
Study SummaryObjective of this study was to find Metabolic signature of C-protein induced myositis mouse model. For metabolite quantification, we used the tissue samples of C-protein induced myositis mouse model and control. Biocrates p180 kit enables to quantify 188 metabolites including amino acids, biogenic amines, acylcarnitine, glycerophospholipid and sugar. Significant metabolites were selected by t-test with false discovery rate p-value less than 0.05. In mouse tissue sample, a total of 68 metabolites significantly changed in CIM mice. We did pathway analysis to find altered pathway in muscle tissue. Metabolites from polyamine and beta-alanine pathway were altered.
Institute
Seoul National University
Last NameKang
First NameJihyun
Address502ho Intergrative Biomedical Education Research Building, 101 Deahakro, Jongro-gu, Seoul, 03080, Korea, South Korea
Emailjikang@snu.ac.kr
Phone+821071014069
Submit Date2022-06-15
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2022-07-14
Release Version1
Jihyun Kang Jihyun Kang
https://dx.doi.org/10.21228/M8RM5T
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Sample Preparation:

Sampleprep ID:SP002289
Sampleprep Summary:Centrifuge the calibration standards, QC, and ISTD mix vials before opening at 10 000 x g (rcf) for 2 min. Dissolve calibration standards (red caps) in 100 µL water. Dissolve QCs (green, blue and yellow caps) in 100 µL water. Dissolve ISTD mix (orange cap) in 1200 µL water. Shake all vials (Cal, QCs, ISTD) for 15 min at 1200 rpm and vortex several times. Centrifuge the QCs and your plasma samples for 5 min at 2750 x g (rcf) and 4 °C. Add 10 µL of the ISTD mix to each well of the Kit plate except A1. Pipette 10 µL PBS / Cal / QC / sample according to your plate layout generated by MetIDQTM. Dry for 30 min under nitrogen (using a Nitrogen Evaporator or a Pressure Manifold). Prepare the pre-mix for derivatization in the plastic tube of the Kit box (1900 µL of each: ethanol, water and pyridine). Add 300 µL phenylisothiocyanate (PITC) and vortex rigorously (at least 10 sec) until the derivatization solution is clear. Make half of the solution for the starter kit. Add 50 µL of the derivatization solution to each well using a repeater at maximum dispensing speed. Cover the plate with the plastic lid and incubate for 25 min, then dry for 60 min under nitrogen. Prepare extraction solvent and add 300 µL to each well. You can use the repeater at low dispensing speed or an 8-channel pipette. Shake for 30 min at 450 rpm (on the scale of min-max 0-1400 rpm). Centrifuge for 2 min at 500 x g (rcf) or use a Pressure Manifold. Visually check that the fill level is the same in all wells of the capture plate. If not, repeat and apply higher g or higher pressure, respectively. Carefully remove the upper filter plate and transfer the volume specified for your instrument to another empty 96-deep well plate that you find in the Kit box (label “LC plate”). Use an 8-channel pipette. Finish the LC plate and dilute the extracts as described for your instrument Prepare the FIA plate and dilute the original extracts as described for your instrument Seal both plates with the silicon mat. Firmly press the mat’s naps into the wells. Shake both plates for 2 min at 600 rpm. Put the plates in the autosampler.
  logo