Summary of Study ST000478

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000364. The data can be accessed directly via it's Project DOI: 10.21228/M80K61 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000478
Study TitleNMR based Metabolomics Analysis of Liver from C57BL/6 Mouse Exposed to Ionizing Radiation
Study SummaryTissue extracts from ionizing readiation exposed mouse liver and controls were compared via NMR based metabolomic analysis
Institute
Pacific Northwest National Laboratory
DepartmentFundamental & Computational Sciences
Last NameHu
First NameJianzhi
AddressPacific Northwest National Laboratory, Richland, WA 99352
EmailJianzhi.Hu@pnnl.gov
Phone+1 (509) 371-6544
Submit Date2016-08-11
Raw Data AvailableYes
Raw Data File Type(s)fid
Analysis Type DetailNMR
Release Date2017-07-10
Release Version1
Jianzhi Hu Jianzhi Hu
https://dx.doi.org/10.21228/M80K61
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Treatment:

Treatment ID:TR000513
Treatment Summary:A total of 27 seven-week-old C57BL/6 female mice randomly into 6 groups, and then whole body being exposed to either gamma or proton radiation. The individually housed animals were fed a standard diet and maintained in an environment controlled facility with an ambient temperature of 22-25°C and 45% relative humidity on 12 h light-dark cycle. Mice were exposed to whole body gamma radiation using a high-activity source (1250 keV 60Co) with the linear energy transfer (LET) associated with these fields in the range of 0.2-2 keV/μm. The mice were isolated in the corner of their polymer cages and placed a minimum of 100 cm from the collimated 6000 Ci (222 TBq) 60Co source, and then irradiation to the proposed dosage, respectively. The result of absorbed dose rate at a depth of approximately 600 mg/cm2 were ~0.83 Gy/min relative to tissue. After irradiation the isolation barrier was removed and mice were transferred to Animal Facility.Mice placed into aerated polystyrene boxes immediately before exposure to the entrance region of proton at the BNL Alternating Gradient Synchrotron (AGS) (1055 MeV/nucleon at the target, with a track-averaged LET =148.2 keV/μm at target). Doses of 0 and 3.0 Gy were delivered to a maximum of four mice at ~0.83 Gy/min in a single fraction. All procedures (i.e., placement in aerated boxes and subsequent tissue harvesting) for the control mice were identical to those of irradiated animals, except that they received no radiation.
  logo