This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001586. The data can be accessed directly via it's Project DOI: 10.21228/M8PQ70 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002459 |
Study Title | Comparison of metabolite profiles from matched whole blood microsamplers, whole blood dried blood spots, and plasma. |
Study Summary | Venous blood was collected from 54 adult female participants from the PRISM cohort. Whole blood and venous blood was aliquoted. Untargeted metabolomics was performed on whole blood collected on Mitra microsamplers (VAMS, 10 uL), whole blood dried blood spots (DBS, 5-mm punch), and 10 uL of plasma |
Institute | Icahn School of Medicine at Mount Sinai |
Last Name | Petrick |
First Name | Lauren |
Address | 1428 Madison Avenue, Atran Building |
lauren.petrick@mssm.edu | |
Phone | 9739976141 |
Submit Date | 2023-01-22 |
Total Subjects | 54 |
Num Females | 54 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzML |
Analysis Type Detail | LC-MS |
Release Date | 2024-01-22 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Project:
Project ID: | PR001586 |
Project DOI: | doi: 10.21228/M8PQ70 |
Project Title: | Untargeted metabolomics in microsamplers, dried blood spots, and plasma |
Project Summary: | Developing robust untargeted metabolomics methods for DBS and microsampler analysis in ECHO |
Institute: | Icahn School of Medicine at Mount Sinai |
Last Name: | Petrick |
First Name: | Lauren |
Address: | 1428 Madison Avenue, Atran Building |
Email: | lauren.petrick@mssm.edu |
Phone: | 9739976141 |
Subject:
Subject ID: | SU002549 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Factors:
Subject type: Human; Subject species: Homo sapiens (Factor headings shown in green)
mb_sample_id | local_sample_id | SampleType | Sampler |
---|---|---|---|
SA246099 | matrixP1 | matrix | DBS |
SA246100 | matrixP2 | matrix | DBS |
SA246103 | matrixD1 | matrix | plasma |
SA246104 | matrixD2 | matrix | plasma |
SA246101 | matrixV1 | matrix | VAM |
SA246102 | matrixV2 | matrix | VAM |
SA246080 | LQC12 | PooledQC | LQC |
SA246081 | LQC11 | PooledQC | LQC |
SA246082 | LQC9 | PooledQC | LQC |
SA246083 | LQC13 | PooledQC | LQC |
SA246084 | LQC10 | PooledQC | LQC |
SA246085 | LQC15 | PooledQC | LQC |
SA246086 | LQC19 | PooledQC | LQC |
SA246087 | LQC18 | PooledQC | LQC |
SA246088 | LQC16 | PooledQC | LQC |
SA246089 | LQC8 | PooledQC | LQC |
SA246090 | LQC14 | PooledQC | LQC |
SA246091 | LQC17 | PooledQC | LQC |
SA246092 | LQC1 | PooledQC | LQC |
SA246093 | LQC7 | PooledQC | LQC |
SA246094 | LQC3 | PooledQC | LQC |
SA246095 | LQC2 | PooledQC | LQC |
SA246096 | LQC5 | PooledQC | LQC |
SA246097 | LQC6 | PooledQC | LQC |
SA246098 | LQC4 | PooledQC | LQC |
SA246105 | 71303-01D | sample | DBS |
SA246106 | 71141-01D | sample | DBS |
SA246107 | 71585-01D | sample | DBS |
SA246108 | 71589-01D | sample | DBS |
SA246109 | 70490-01D | sample | DBS |
SA246110 | 72021-01D | sample | DBS |
SA246111 | 70098-01D | sample | DBS |
SA246112 | 71944-01D | sample | DBS |
SA246113 | 71688-01D | sample | DBS |
SA246114 | 71843-01D | sample | DBS |
SA246115 | 71766-01D | sample | DBS |
SA246116 | 70607-01D | sample | DBS |
SA246117 | 70645-01D | sample | DBS |
SA246118 | 71551-01D | sample | DBS |
SA246119 | 72144-01D | sample | DBS |
SA246120 | 72108-01D | sample | DBS |
SA246121 | 71050-01D | sample | DBS |
SA246122 | 72031-01D | sample | DBS |
SA246123 | 71409-01D | sample | DBS |
SA246124 | 70467-01D | sample | DBS |
SA246125 | 70522-01D | sample | DBS |
SA246126 | 70732-01D | sample | DBS |
SA246127 | 71528-01D | sample | DBS |
SA246128 | 71917-01D | sample | DBS |
SA246129 | 71707-01D | sample | DBS |
SA246130 | 71867-01D | sample | DBS |
SA246131 | 70214-02D | sample | DBS |
SA246132 | 71185-01D | sample | DBS |
SA246133 | 70404-01D | sample | DBS |
SA246134 | 71678-01D | sample | DBS |
SA246135 | 71289-01D | sample | DBS |
SA246136 | 70808-01D | sample | DBS |
SA246137 | 70705-01D | sample | DBS |
SA246138 | 71674-01D | sample | DBS |
SA246139 | 71664-01D | sample | DBS |
SA246140 | 70468-01D | sample | DBS |
SA246141 | 71564-01D | sample | DBS |
SA246142 | 71747-01D | sample | DBS |
SA246143 | 70557-01D | sample | DBS |
SA246144 | 70978-01D | sample | DBS |
SA246145 | 71330-01D | sample | DBS |
SA246146 | 71446-01D | sample | DBS |
SA246147 | 70226-03D | sample | DBS |
SA246148 | 70632-01D | sample | DBS |
SA246149 | 70833-01D | sample | DBS |
SA246150 | 71751-01D | sample | DBS |
SA246151 | 71906-01D | sample | DBS |
SA246152 | 71530-01D | sample | DBS |
SA246153 | 72173-01D | sample | DBS |
SA246154 | 70784-01D | sample | DBS |
SA246155 | 70969-01D | sample | DBS |
SA246156 | 70823-02D | sample | DBS |
SA246157 | 71522-01D | sample | DBS |
SA246158 | 71939-01D | sample | DBS |
SA246213 | 71843-01P | sample | plasma |
SA246214 | 70467-01P | sample | plasma |
SA246215 | 71330-01P | sample | plasma |
SA246216 | 70522-01P | sample | plasma |
SA246217 | 71551-01P | sample | plasma |
SA246218 | 72021-01P | sample | plasma |
SA246219 | 70833-01P | sample | plasma |
SA246220 | 70404-01P | sample | plasma |
SA246221 | 70632-01P | sample | plasma |
SA246222 | 71528-01P | sample | plasma |
SA246223 | 71917-01P | sample | plasma |
SA246224 | 72173-01P | sample | plasma |
SA246225 | 70969-01P | sample | plasma |
SA246226 | 70214-02P | sample | plasma |
SA246227 | 70732-01P | sample | plasma |
SA246228 | 71867-01P | sample | plasma |
SA246229 | 70823-02P | sample | plasma |
SA246230 | 71939-01P | sample | plasma |
SA246231 | 71944-01P | sample | plasma |
SA246232 | 70607-01P | sample | plasma |
SA246233 | 71446-01P | sample | plasma |
Collection:
Collection ID: | CO002542 |
Collection Summary: | 54 participants had a venous blood draw into K2EDTA tubes which were aliquoted into whole blood and plasma aliquots. From the whole blood aliquot, whole blood DBS were generated by aliquoting 50 uL onto a Whatman. Whole blood VAMs were collected using the 10 uL Mitra sampling device. 10 uL plasma aliquot was also preserved. |
Sample Type: | Blood (whole) |
Treatment:
Treatment ID: | TR002561 |
Treatment Summary: | This study compares whole blood and plasma from the same participant. There is no treatment |
Sample Preparation:
Sampleprep ID: | SP002555 |
Sampleprep Summary: | In allocated randomized order, 5-mm DBS punches, 10 uL blood microsamplers, and 10 uL plasma aliquots were thawed on ice and placed into microcentrifuge tubes. 100 uL of water was added, vortexed, and 5 uL reserved for hemoglobin analysis. 400 uL of acetonitrile containing internal standards was added, vortexed, stored at -20C overnight to precipitate proteins, and centrifuged the next day. Two aliquots of the supernatant were evaporated to dryness and stored in -80°C until analysis with LC-HRMS. From all samples, 40 uL of the supernatant were combined to generate a pooled QC sample. Following the same extraction protocol a 5-mm blank punch from adjacent Whatman paper and a blank microsampler pen were extracted from 5 participants, respectively. Similarly, plasma was replaced with 10 uL of water and extracted. The respective extracts were pooled to generate a matrix plasma (matrix P), matrix DBS (matrix D), and matrix VAM (matrix V). |
Combined analysis:
Analysis ID | AN004011 | AN004012 | AN004013 |
---|---|---|---|
Analysis type | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | HILIC |
Chromatography system | Agilent 6550 | Agilent 6550 | Agilent 6550 |
Column | Agilent Zorbax StableBond Aq (50 x 2.1mm,1.8um) | Agilent ZORBAX Eclipse Plus C18 (50 x 2.1mm,1.8um) | SeQuant ZIC-HILIC (100 x 2.1mm,3.5um) |
MS Type | ESI | ESI | ESI |
MS instrument type | QTOF | QTOF | QTOF |
MS instrument name | Agilent 6550 QTOF | Agilent 6550 QTOF | Agilent 6545 QTOF |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE |
Units | Ion abundance | Ion abundance | Ion abundance |
Chromatography:
Chromatography ID: | CH002962 |
Chromatography Summary: | Reverse-phase positive |
Instrument Name: | Agilent 6550 |
Column Name: | Agilent Zorbax StableBond Aq (50 x 2.1mm,1.8um) |
Column Temperature: | 60 |
Flow Gradient: | 2–98% B in 13 min, hold at 98% B for 6 min |
Flow Rate: | 0.550 mL/min flow rate |
Solvent A: | 0.2% acetic acid in water |
Solvent B: | 0.2% acetic acid in methanol |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH002963 |
Chromatography Summary: | Reverse-phase negative |
Instrument Name: | Agilent 6550 |
Column Name: | Agilent ZORBAX Eclipse Plus C18 (50 x 2.1mm,1.8um) |
Column Temperature: | 50 |
Flow Gradient: | 5% B for 2 min, increasing to 30% B in 2 min, and increasing from 30% to 98% B in 9.5 min with a 1.5 min hold |
Flow Rate: | 0.400 mL/min flow rate |
Solvent A: | 0.1% formic acid in water |
Solvent B: | 0.1% formic acid in (90:10, v/v) 2-propanol:ACN |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH002964 |
Chromatography Summary: | HILIC positive |
Instrument Name: | Agilent 6550 |
Column Name: | SeQuant ZIC-HILIC (100 x 2.1mm,3.5um) |
Column Temperature: | 25 |
Flow Gradient: | 95% B for 1.5 min, decreasing to 40% B in 10.5 min, followed by a 2 min hold, a decrease to 25% B in 0.2 min and a hold for 2.8 min at 25%B |
Flow Rate: | 0.300 mL/min flow rate |
Solvent A: | 0.1% formic acid in water |
Solvent B: | 0.1% formic acid in acetonitrile |
Chromatography Type: | HILIC |
MS:
MS ID: | MS003758 |
Analysis ID: | AN004011 |
Instrument Name: | Agilent 6550 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Full mass spectra were acquired at 1.67 spectra/s in the range 50–1000 m/z. Data files were divided according to respective groupings of samples, pooled QC, and matrix samples. Parameters for peak picking grouping, and alignment with ‘XCMS’ included centwave feature detection, orbiwarp retention time correction, minimum fraction of samples in one group to be a valid group = 0.25, isotopic ppm error = 10. The resulting peak table of retention times, m/z values, and peak areas was exported for data processing. Missing values in the peak table were filled using the peakFill() function in XCMS. |
Ion Mode: | POSITIVE |
MS ID: | MS003759 |
Analysis ID: | AN004012 |
Instrument Name: | Agilent 6550 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Full mass spectra were acquired at 1.67 spectra/s in the range 40–1200 m/z.arameters for peak picking grouping, and alignment with ‘XCMS’ included centwave feature detection, orbiwarp retention time correction, minimum fraction of samples in one group to be a valid group = 0.25, isotopic ppm error = 10. The resulting peak table of retention times, m/z values, and peak areas was exported for data processing. Missing values in the peak table were filled using the peakFill() function in XCMS. |
Ion Mode: | NEGATIVE |
MS ID: | MS003760 |
Analysis ID: | AN004013 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Full mass spectra were acquired at 1.67 spectra/s in the range 40–1200 m/z. Parameters for peak picking grouping, and alignment with ‘XCMS’ included centwave feature detection, orbiwarp retention time correction, minimum fraction of samples in one group to be a valid group = 0.25, isotopic ppm error = 10. The resulting peak table of retention times, m/z values, and peak areas was exported for data processing. Missing values in the peak table were filled using the peakFill() function in XCMS. |
Ion Mode: | POSITIVE |