MoNA MS database records for L-Cystathionine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA018166 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA018167 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
MoNA018168 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M-H]- | negative | MS2 |
MoNA019709 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA019710 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA019711 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M+H]+ | positive | MS2 |
MoNA019712 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
PM000962 | API 2000 | QqQ | ESI | 20 | [M+H]+ | positive | MS2 |
RP014611 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP014612 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
RP014601 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP014602 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP014603 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
MoNA024178 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
PS066501 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS066502 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS018703 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS066503 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS066504 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS018705 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS066505 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS066506 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |
PR100535 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100114 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M+H]+ | positive | MS2 |
PR100113 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
MoNA019517 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA019520 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA019518 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA019521 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA019519 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA019522 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA011004 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA011005 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA011006 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
MoNA011007 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA033927 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034935 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA033925 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034933 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA033924 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA034934 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA032014 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032734 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA035949 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032016 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032735 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA035951 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032017 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA032737 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA035953 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
KO002572 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO002573 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO002574 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO002575 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO002576 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
KO008910 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.55 | [M+H]+ | positive | MS2 |
KO008911 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.55/0.55 | [M+H]+ | positive | MS3 |
CCMSLIB00005464430 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464481 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
KZ000116 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010026 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000578190 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000577955 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720685 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720393 | qTof | - | - | - | [M+H]+ | positive | MS2 |
FiehnHILIC002652 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC001861 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC001133 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA037833 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC000288 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037059 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037129 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038527 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
EMBL-MCF_spec41597 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec112852 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
MoNA016889 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+Na]+ | positive | - |
HMDB0000099_ms_ms_156 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000099_ms_ms_157 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000099_ms_ms_158 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000099_c_ms_1814 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000099_c_ms_1842 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000099_c_ms_1869 | XEVO-G2S | GC-MS | - | - | - | - | - |