MoNA MS database records for Histamine

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
AU530907Bruker maXis ImpactLC-ESI-QTOFESI10 eV[M+H]+positiveMS2
BAF_UVA_POS001576Bruker maXis Impact------
BAF_UVA_POS001577Bruker maXis Impact------
BAF_UVA_POS001578Bruker maXis Impact------
BML81400Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---positiveMS1
BML81401Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---negativeMS1
BML81402Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF---positiveMS1
CCMSLIB00000578003Q-Exactive Plus---[M+H]+positiveMS2
CCMSLIB00000578248Q-Exactive Plus---[M-H]-negativeMS2
CCMSLIB00005463936Orbitrap---[M+H]+positiveMS2
CCMSLIB00005720444qTof---[M+H]+positiveMS2
EMBL-MCF_spec123342Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M+H]+positiveMS2
EMBL-MCF_spec123437Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M+H]+positiveMS2
EMBL-MCF_spec52323Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M-H]-negativeMS2
FiehnHILIC000413Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
FiehnHILIC001245Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
HMDB0000870_c_ms_1293Thermo Q Exactive HFGC-MS-----
HMDB0000870_c_ms_1582Thermo Q Exactive HFGC-MS-----
HMDB0000870_ei_ms_425Thermo Q Exactive HF------
HMDB0000870_ms_ms_1223Thermo Q Exactive HFQuattro_QQQ---positive-
HMDB0000870_ms_ms_1224Thermo Q Exactive HFQuattro_QQQ---positive-
HMDB0000870_ms_ms_1225Thermo Q Exactive HFQuattro_QQQ---positive-
HMDB0060263_c_ms_1293Thermo Q Exactive HFGC-MS-----
HMDB0060263_c_ms_1582Thermo Q Exactive HFGC-MS-----
HMDB0060263_ei_ms_425Thermo Q Exactive HF------
HMDB0060263_ms_ms_1223Thermo Q Exactive HFQuattro_QQQ---positive-
HMDB0060263_ms_ms_1224Thermo Q Exactive HFQuattro_QQQ---positive-
HMDB0060263_ms_ms_1225Thermo Q Exactive HFQuattro_QQQ---positive-
KO003128API3000, Applied BiosystemsLC-ESI-QQ-10 V[M+H]+positiveMS2
KO003129API3000, Applied BiosystemsLC-ESI-QQ-20 V[M+H]+positiveMS2
KO003130API3000, Applied BiosystemsLC-ESI-QQ-30 V[M+H]+positiveMS2
KO003131API3000, Applied BiosystemsLC-ESI-QQ-40 V[M+H]+positiveMS2
KO003132API3000, Applied BiosystemsLC-ESI-QQ-50 V[M+H]+positiveMS2
KZ000214Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
MoNA001986Agilent QTOF 6550LC-ESI-QTOF-10[M+H]+positiveMS2
MoNA001987Agilent QTOF 6550LC-ESI-QTOF-20[M+H]+positiveMS2
MoNA001989Agilent QTOF 6550LC-ESI-QTOF-40[M+H]+positiveMS2
MoNA010708Agilent 6550 iFunnelLC-ESI-QTOF--[M+H]+PositiveMS2
MoNA010709Agilent 6550 iFunnelLC-ESI-QTOF-10[M+H]+PositiveMS2
MoNA010710Agilent 6550 iFunnelLC-ESI-QTOF-30[M+H]+PositiveMS2
MoNA016721XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+H]+positive-
MoNA024068Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
MoNA032172Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA032173Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA032176Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA036100Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA036101Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA036102Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA037194Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA038578Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA041268Thermo Q Exactive HF-Electrospray Ionization (ESI)-M+HpositiveMS2
OUF00266Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
PR010122Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
PR100071UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
PS012601TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS012602TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS012603TQD, WatersFlow-injection QqQ/MSESI30[M+H]+positiveMS2
PT101260Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2