#METABOLOMICS WORKBENCH Davidobe12_20180613_060330 DATATRACK_ID:1413 STUDY_ID:ST000980 ANALYSIS_ID:AN001604 PROJECT_ID:PR000670
VERSION             	1
CREATED_ON             	June 19, 2018, 12:17 pm
#PROJECT
PR:PROJECT_TITLE                 	Metabolomics analysis of plasma samples from non-allergic subjects and patients
PR:PROJECT_TITLE                 	with different severity of food allergy
PR:PROJECT_SUMMARY               	Metabolomic analysis of plasma samples from grass pollen allergic patients with
PR:PROJECT_SUMMARY               	different levels of allergic severity to profilin.
PR:INSTITUTE                     	Institute of Applied Molecular Medicine and The Centre of Metabolomics and
PR:INSTITUTE                     	Bioanalysis
PR:DEPARTMENT                    	Analytical chemistry
PR:LAST_NAME                     	Barber Hernández
PR:FIRST_NAME                    	Domingo
PR:ADDRESS                       	Avda. Monteprincipe s/n 28668 Boadilla del Monte, Madrid, España
PR:EMAIL                         	domingo.barberhernandez@ceu.es
PR:PHONE                         	+34 91 372 47 00 ext.4662
#STUDY
ST:STUDY_TITLE                   	Metabolomic Analysis of plasma samples from Non-Allergic Subjects and
ST:STUDY_TITLE                   	Profilin-Allergic Patients overexposed to Grass Pollen
ST:STUDY_TYPE                    	Allergy severity comparison
ST:STUDY_SUMMARY                 	Prevalence and severity of allergic diseases have increased worldwide. To date,
ST:STUDY_SUMMARY                 	respiratory allergy phenotypes are not fully characterized and, along with
ST:STUDY_SUMMARY                 	inflammation progression, treatment is increasingly complex and expensive.
ST:STUDY_SUMMARY                 	Profilin sensitization constitutes a good model to study the progression of
ST:STUDY_SUMMARY                 	allergic inflammation. Our aim was to identify the underlying mechanisms and the
ST:STUDY_SUMMARY                 	associated biomarkers of this progression, focusing on severe phenotypes, using
ST:STUDY_SUMMARY                 	transcriptomics and metabolomics. Methods: 25 subjects were included in the
ST:STUDY_SUMMARY                 	study. Plasma samples were analyzed using Gas and Liquid Chromatography coupled
ST:STUDY_SUMMARY                 	to Mass Spectrometry (GC-MS and LC-MS, respectively). Individuals were
ST:STUDY_SUMMARY                 	classified in 4 groups – “non-allergic”, “mild”, “moderate” and
ST:STUDY_SUMMARY                 	“severe” – based on their clinical history, their response to an oral
ST:STUDY_SUMMARY                 	challenge test with profilin, and after a refinement using a mathematical
ST:STUDY_SUMMARY                 	metabolomic model. PBMCs were used for microarray analysis.
ST:INSTITUTE                     	The Centre of Metabolomics and Bioanalysis
ST:DEPARTMENT                    	Analytical chemistry
ST:LAST_NAME                     	Obeso Montero
ST:FIRST_NAME                    	David
ST:ADDRESS                       	Avda. Monteprincipe s/n 28668 Boadilla del Monte, Madrid, España
ST:EMAIL                         	david.obesomontero@beca.ceu.es
ST:PHONE                         	913724769
ST:NUM_GROUPS                    	4 groups
ST:TOTAL_SUBJECTS                	25 plasma samples
#SUBJECT
SU:SUBJECT_TYPE                  	Human
SU:SUBJECT_SPECIES               	Homo sapiens
SU:TAXONOMY_ID                   	9606
#SUBJECT_SAMPLE_FACTORS:         	SUBJECT(optional)[tab]SAMPLE[tab]FACTORS(NAME:VALUE pairs separated by |)[tab]Additional sample data
SUBJECT_SAMPLE_FACTORS           	P1	02_005	Classification:Non-allergic	
SUBJECT_SAMPLE_FACTORS           	P2	02_006	Classification:Non-allergic	
SUBJECT_SAMPLE_FACTORS           	P3	02_007	Classification:Non-allergic	
SUBJECT_SAMPLE_FACTORS           	P4	02_008	Classification:Non-allergic	
SUBJECT_SAMPLE_FACTORS           	P5	04_003	Classification:Non-allergic	
SUBJECT_SAMPLE_FACTORS           	P6	04_006	Classification:Non-allergic	
SUBJECT_SAMPLE_FACTORS           	P7	01_001	Classification:Mild	
SUBJECT_SAMPLE_FACTORS           	P8	01_002	Classification:Mild	
SUBJECT_SAMPLE_FACTORS           	P9	02_002	Classification:Mild	
SUBJECT_SAMPLE_FACTORS           	P10	02_003	Classification:Mild	
SUBJECT_SAMPLE_FACTORS           	P11	04_001	Classification:Mild	
SUBJECT_SAMPLE_FACTORS           	P12	01_005	Classification:Moderate	
SUBJECT_SAMPLE_FACTORS           	P13	02_001	Classification:Moderate	
SUBJECT_SAMPLE_FACTORS           	P14	02_004	Classification:Moderate	
SUBJECT_SAMPLE_FACTORS           	P15	03_004	Classification:Moderate	
SUBJECT_SAMPLE_FACTORS           	P16	03_098	Classification:Moderate	
SUBJECT_SAMPLE_FACTORS           	P17	04_002	Classification:Moderate	
SUBJECT_SAMPLE_FACTORS           	P18	03_002	Classification:Severe	
SUBJECT_SAMPLE_FACTORS           	P19	03_003	Classification:Severe	
SUBJECT_SAMPLE_FACTORS           	P20	03_092	Classification:Severe	
SUBJECT_SAMPLE_FACTORS           	P21	03_093	Classification:Severe	
SUBJECT_SAMPLE_FACTORS           	P22	03_094	Classification:Severe	
SUBJECT_SAMPLE_FACTORS           	P23	03_095	Classification:Severe	
SUBJECT_SAMPLE_FACTORS           	P24	03_096	Classification:Severe	
SUBJECT_SAMPLE_FACTORS           	P25	03_099	Classification:Severe	
#COLLECTION
CO:COLLECTION_SUMMARY            	Whole blood was drawn before the profilin challenge and was divided into two
CO:COLLECTION_SUMMARY            	tubes: one for plasma extraction and other for PBMCs isolation. Briefly, 20 ml
CO:COLLECTION_SUMMARY            	of peripheral blood were collected to obtain plasma by centrifugation(1500rpm x
CO:COLLECTION_SUMMARY            	5 min.) and PBMCs using Ficoll-Paque (GE Healthcare™) density gradient
CO:COLLECTION_SUMMARY            	centrifugation.
CO:SAMPLE_TYPE                   	Blood (whole)
CO:COLLECTION_LOCATION           	Hospital Universitario Clínico San Carlos, Madrid, España. Hospital
CO:COLLECTION_LOCATION           	Universitario de La Princesa, Instituto de Investigación Sanitaria Princesa
CO:COLLECTION_LOCATION           	(IP), Madrid, España. Hospital Virgen del Puerto, Plasencia, Cáceres, España.
CO:COLLECTION_LOCATION           	Hospital Universitario HM Sanchinarro, Madrid, España.
CO:VOLUMEORAMOUNT_COLLECTED      	14-16 mL Blood
CO:STORAGE_CONDITIONS            	-80℃
CO:COLLECTION_VIALS              	BD Vacutainer® Heparin Blood Collection Tubes (Ref. BD367871)
CO:STORAGE_VIALS                 	Eppendorf 1.5 mL
CO:COLLECTION_TUBE_TEMP          	Room Temperature
#TREATMENT
TR:TREATMENT_SUMMARY             	No treatment was used in this study.
#SAMPLEPREP
SP:SAMPLEPREP_SUMMARY            	For LC-MS, plasma protein was removed adding 300 µL of cold (-20 °C)
SP:SAMPLEPREP_SUMMARY            	methanol:ethanol (1:1) to 100 µL of sample. Samples were then vortex-mixed and
SP:SAMPLEPREP_SUMMARY            	stored on ice for 5 min. Supernatant containing the metabolites was separated
SP:SAMPLEPREP_SUMMARY            	from the pellet by centrifugation (16,000× g for 20 min at 4 °C), and put into
SP:SAMPLEPREP_SUMMARY            	a LC vial for analysis. For GC-MS protein precipitation, 120 μL of cold
SP:SAMPLEPREP_SUMMARY            	acetonitrile (ACN) were added to 40 μL of each plasma sample in an Eppendorf
SP:SAMPLEPREP_SUMMARY            	and were stored on ice for 5 minutes. Then, metabolites were separated by
SP:SAMPLEPREP_SUMMARY            	centrifugation (16,000× g, 15 min, 4 °C). From the resulting supernatant, 100
SP:SAMPLEPREP_SUMMARY            	μL were transferred to GC vial with insert and were evaporated to dryness
SP:SAMPLEPREP_SUMMARY            	(SpeedVac Concentrator, Thermo Fisher Scientific, Waltham, MA, USA). Then, 10
SP:SAMPLEPREP_SUMMARY            	μL of O-methoxyamine hydrochloride in pyridine (15 mg/mL) was added to each GC
SP:SAMPLEPREP_SUMMARY            	vial, and the mixture was vigorously vortex-mixed and ultrasonicated.
SP:SAMPLEPREP_SUMMARY            	Methoxymation was carried out in darkness, at room temperature for 16 h.
SP:SAMPLEPREP_SUMMARY            	Afterwards, 10 μL of N,O-Bis(trimethylsilyl)trifluoroacetamide (BSTFA) with 1%
SP:SAMPLEPREP_SUMMARY            	trimethylchlorosilane (TMCS) were added as catalyst and the solution was further
SP:SAMPLEPREP_SUMMARY            	mixed using the vortex. For silylation process, samples were heated in an oven
SP:SAMPLEPREP_SUMMARY            	for 1h at 70 °C. Finally, 100 μL of heptane containing 10 ppm of C18:0 methyl
SP:SAMPLEPREP_SUMMARY            	ester (IS) were added to each GC vial and vortex-mixed before GC analysis.
#CHROMATOGRAPHY
CH:CHROMATOGRAPHY_SUMMARY        	For LC-MS, 10 μL of sample were injected into a Discovery HS C18 column (2.1 mm
CH:CHROMATOGRAPHY_SUMMARY        	× 150 mm, 3.0 μm; Supelco, Sigma Aldrich, Germany), with a guard column
CH:CHROMATOGRAPHY_SUMMARY        	Discovery® HS C18 (2 cm × 2.1 mm, 3 μm; Supelco, Sigma Aldrich, Germany),
CH:CHROMATOGRAPHY_SUMMARY        	both maintained at 40 °C. The flow rate was set at 0.6 mL/min. The gradient
CH:CHROMATOGRAPHY_SUMMARY        	elution involved a mobile phase consisting of (A) 0.1% formic acid (FA) in water
CH:CHROMATOGRAPHY_SUMMARY        	and (B) 0.1% FA in acetonitrile (ACN). The initial condition was set at 25% B,
CH:CHROMATOGRAPHY_SUMMARY        	increasing to 95% B in 35 min, followed by re-equilibration for 1 min, finally
CH:CHROMATOGRAPHY_SUMMARY        	it was held for 9 min in initial conditions. Flow rate was set at 0.6 mL/min,
CH:CHROMATOGRAPHY_SUMMARY        	and 10 μL of samples were injected. The electrospray source ionization (ESI)
CH:CHROMATOGRAPHY_SUMMARY        	data were acquired in positive and negative ion mode, respectively. The
CH:CHROMATOGRAPHY_SUMMARY        	capillary voltage was set at 3,500 for ESI (+) and 4,000V for ESI (−). The
CH:CHROMATOGRAPHY_SUMMARY        	drying gas flow rate was 10.5 L/min at 330 °C and gas nebulizer at 52 psi;
CH:CHROMATOGRAPHY_SUMMARY        	fragmentor voltage was 175 V; skimmer and octopole radio frequency voltage (OCT
CH:CHROMATOGRAPHY_SUMMARY        	RF Vpp) were set to 65 and 750 V. Data were collected in the centroid mode at a
CH:CHROMATOGRAPHY_SUMMARY        	scan rate of 1.2 spectra per second. Mass spectrometry detection was performed
CH:CHROMATOGRAPHY_SUMMARY        	in full scan from 100 to 1200 m/z for both, positive and negative ESI mode. The
CH:CHROMATOGRAPHY_SUMMARY        	reference m/z ions were purine (121.0508) and HP-0921 (922.0097) for ESI (+),
CH:CHROMATOGRAPHY_SUMMARY        	whereas TFA NH4 (119.0363) and HP-0921 (966.0007) for ESI (−). These masses
CH:CHROMATOGRAPHY_SUMMARY        	were continuously infused into the system to allow constant mass correction.
CH:CHROMATOGRAPHY_SUMMARY        	Samples were analyzed in separate runs.
CH:CHROMATOGRAPHY_TYPE           	Normal phase
CH:INSTRUMENT_NAME               	Agilent 1200
CH:COLUMN_NAME                   	Unspecified
#ANALYSIS
AN:ANALYSIS_TYPE                 	MS
#MS
MS:MS_COMMENTS                   	-
MS:INSTRUMENT_NAME               	Agilent 6520 QTOF
MS:INSTRUMENT_TYPE               	QTOF
MS:MS_TYPE                       	ESI
MS:ION_MODE                      	POSITIVE
MS:CAPILLARY_VOLTAGE             	3500 V
MS:DRY_GAS_FLOW                  	10.5 L/min
MS:DRY_GAS_TEMP                  	330 °C
MS:FRAGMENT_VOLTAGE              	175 V
MS:MS_RESULTS_FILE               	ST000980_AN001604_Results.txt	UNITS:peak area
#END