                         INSTRUMENT CONTROL PARAMETERS:    7890A_5975C
                         ---------------------------------------------

   C:\MSDCHEM\1\METHODS\FAME40PSPLIT10.M
      Thu Dec 04 03:56:17 2014

Control Information
------- -----------

Sample Inlet      :  GC
Injection Source  :  GC ALS
Mass Spectrometer :  Enabled


 No Sample Prep method has been assigned to this method.

Oven
Equilibration Time                           0.1 min
Max Temperature                              325 degrees C
Slow Fan                                     Disabled
Oven Program                                 On
    80 C for 1 min
#1    then 20 C/min to 160 C for 0 min
#2    then 2 C/min to 220 C for 0 min
#3    then 15 C/min to 310 C for 2 min
Run Time                                     43 min
Cryo                                         Off

Front Injector
Syringe Size                                 10 L
Injection Volume                             0.5 L
Solvent A Washes (PreInj)                    2
Solvent A Washes (PostInj)                   3
Solvent A Volume                             8 L
Solvent B Washes (PreInj)                    0
Solvent B Washes (PostInj)                   0
Solvent B Volume                             8 L
Sample Washes                                0
Sample Wash Volume                           8 L
Sample Pumps                                 6
Dwell Time (PreInj)                          0 min
Dwell Time (PostInj)                         0 min
Solvent Wash Draw Speed                      300 L/min
Solvent Wash Dispense Speed                  6000 L/min
Sample Wash Draw Speed                       300 L/min
Sample Wash Dispense Speed                   6000 L/min
Injection Dispense Speed                     6000 L/min
Viscosity Delay                              0 sec
Sample Depth                                 Disabled
Injection Type                               Standard
L1 Airgap                                    0.2 L

Sample Overlap
Sample overlap is not enabled

Front SS Inlet He
Mode                                         Pulsed Split
Heater                                       On    250 C
Pressure                                     On    9.3825 psi
Total Flow                                   On    14 mL/min
Septum Purge Flow                            On    3 mL/min
Gas Saver                                    On    20 mL/min After 2 min
Split Ratio                                  10 :1
Split Flow                                   10 mL/min
Injection Pulse Pressure                     10 psi Until 0.75 min

Thermal Aux 2 (MSD Transfer Line)
Heater                                       On
Temperature Program                          On
    280 C for 0 min
Run Time                                     43 min

Column #1
Agilent 19091S-433: HP-5ms
HP-5MS  5% Phenyl Methyl Silox
325 C: 30 m x 250 m x 0.25 m
In: Front SS Inlet He
Out: Vacuum

(Initial)                                    80 C
Pressure                                     9.3825 psi
Flow                                         1 mL/min
Average Velocity                             36.966 cm/sec
Holdup Time                                  1.3526 min
Flow Program                                 On
    1 mL/min for 0 min
Run Time                                     43 min

Signals
Signal #1: Test Plot                         Save Off
                                             50 Hz

Signal #2: Test Plot                         Save Off
                                             50 Hz

Signal #3: Test Plot                         Save Off
                                             50 Hz

Signal #4: Test Plot                         Save Off
                                             50 Hz

                                MS ACQUISITION PARAMETERS


General Information
------- -----------

Tune File                : atune.u
Acquistion Mode          : Scan


MS Information
-- -----------

Solvent Delay            : 7.00 min

EMV Mode                 : Relative
Relative Voltage         : 0
Resulting EM Voltage     : 1047

[Scan Parameters]

Low Mass                 : 40.0
High Mass                : 550.0
Threshold                : 0
Sample #                 : 2       A/D Samples    4

[MSZones]

MS Source                : 230 C   maximum 250 C
MS Quad                  : 150 C   maximum 200 C


                             END OF MS ACQUISITION PARAMETERS


                              TUNE PARAMETERS for SN: US12254A01
                        -----------------------------

 Trace Ion Detection is OFF.

 EMISSION    :      34.610
 ENERGY      :      69.922
 REPELLER    :      34.814
 IONFOCUS    :      89.208
 ENTRANCE_LE :      16.000
 EMVOLTS     :    1047.059
                               Actual EMV  :    1047.06
                               GAIN FACTOR :       0.37
 AMUGAIN     :    1302.000
 AMUOFFSET   :     121.500
 FILAMENT    :       1.000
 DCPOLARITY  :       1.000
 ENTLENSOFFS :      20.329
 MASSGAIN    :    -987.000   
 MASSOFFSET  :     -38.000   

                           END OF TUNE PARAMETERS
                      ------------------------------------



                              END OF INSTRUMENT CONTROL PARAMETERS
                              ------------------------------------