Return to study ST000522 main page

MB Sample ID: SA027281

Local Sample ID:20150724_YU_2_1_2
Subject ID:SU000544
Subject Type:Animal
Subject Species:Megalobrama amblycephala
Taxonomy ID:75352
Species Group:Fish

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000544
Subject Type:Animal
Subject Species:Megalobrama amblycephala
Taxonomy ID:75352
Species Group:Fish

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
20150724_YU_2_1_2SA027281FL0068652 years old sexually mature without hormone treatmentPhenotype

Collection:

Collection ID:CO000538
Collection Summary:About 2 ml of blood was collected via caudal vein by syringe for each female M.amblycephala and then directly put into K3 EDTA centrifuge tube.
Collection Protocol Filename:Zhou999_20161213_161728_PR_CO_collection_files.docx
Sample Type:Plasma

Treatment:

Treatment ID:TR000558
Treatment Summary:The blood was centrifuged at 4000 rpm for 5 min at 4°C as soon as it was extracted from fish and about 1 ml supernatant was pipetted into another tube.The extracted plasma samples were then frozen in liquid nitrogen immediately and stored in the -80°C.

Sample Preparation:

Sampleprep ID:SP000551
Sampleprep Summary:To initiate the experiment, each plasma sample was mixed with the same volume and labeled as Quality control (QC) sample. Plasma sample (100 µl, including QC sample) was added into new Eppendorf tube with ice-cold methanol (300 µl), vortex mixing for 1 min, standing for 1 min, and make sure the solution volume had no obvious observable difference. Then samples were precipitated for 20 min at -20°C, and centrifuged at 14000 rpm for 20 min at 4°C to precipitate the proteins. A total of 250 µl of protein free supernatant was collected and dried with nitrogen at 37°C. The concentration of extractant was diluted depending on the mass spectrum response signals.
Sampleprep Protocol Filename:Zhou999_20161213_161728_PR_SP_sampleprep.docx

Combined analysis:

Analysis ID AN000796 AN000797
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Waters 2777C Waters 2777C
Column Waters Acquity BEH C18 (150 x 2mm,1.7um) Waters Acquity BEH C18 (150 x 2mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Waters Synapt G2 XS QTOF Waters Synapt G2 XS QTOF
Ion Mode POSITIVE NEGATIVE
Units peak intensity peak intensity

Chromatography:

Chromatography ID:CH000572
Chromatography Summary:Chromatographic separation was performed on a ACQUITY UPLC BEH C18 analytical column (100×2.1 mm, 1.7 µm, Waters, Milford, USA) using a 2777C UPLC system (Waters). The flow rate was 0.40 mL/min and the mobile phase was composed of solvents A (95% H2O/5% acetonitrile + 0.1% formic acid) and B (95% acetonitrile/5% H2O+0.1% formic acid).The gradient program was optimized as follows: 0–0.1 min, 100% A; 0.1–0.6 min, 100% A-50% A; 0.6–5 min, 50%–0% A; 5–8 min, 0% A; 8–10 min, 0% A-100% A. Injection volume was 10 µl. The eluent from the column was directly added in to the mass spectrometer without split.
Instrument Name:Waters 2777C
Column Name:Waters Acquity BEH C18 (150 x 2mm,1.7um)
Flow Gradient:100% acetonitrile
Flow Rate:0.40 mL/min
Solvent A:95% water/5% acetonitrile; 0.1% formic acid
Solvent B:95% acetonitrile/5% water; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS000703
Analysis ID:AN000796
Instrument Name:Waters Synapt G2 XS QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
  
MS ID:MS000704
Analysis ID:AN000797
Instrument Name:Waters Synapt G2 XS QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:NEGATIVE
  logo