Return to study ST000603 main page

MB Sample ID: SA033307

Local Sample ID:160427blvsa10_1
Subject ID:SU000626
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU000626
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
160427blvsa10_1SA033307FL007369controlTreatment

Collection:

Collection ID:CO000620
Collection Summary:First morning urine specimens were obtained using clean catch methods, and sent to clinical laboratory. After a 10 min centrifugation to remove cell debris, urine specimens were stored at −80◦C until further analysis.
Sample Type:Urine

Treatment:

Treatment ID:TR000640
Treatment Summary:No treatment

Sample Preparation:

Sampleprep ID:SP000633
Sampleprep Summary:1. Vortex the urine samples for about 10s to obtain a homogenized sample using the MiniVortexer VWR. 2. Aliquot 15-30ul and add 1ml extraction solution. The extraction solution has to be pre-chilled using the ThermoElectron Neslab RTE 740 cooling bath set to -20°C. 3. Vortex the sample for about 10s and shake for 5min at 4°C using the Orbital Mixing Chilling/Heating plate. If you are using more than one sample, keep the rest of the samples on ice (chilled at <0°C with NaCl). 4. Centrifuge samples for 2min at 14000 rcf using the centrifuge Eppendorf 5415 D. 5. Aliquot 2X 0.5ml supernatant. One for analysis and one for backup. Store 2nd aliquot in -20°C freezer. 6. Evaporate 0.5ml aliquots of the sample in the Labconco Centrivap cold trap concentrator to complete dryness. 7. Submit to derivatization.
Sampleprep Protocol Filename:SOP_Extraction_of_Urine.pdf

Combined analysis:

Analysis ID AN000923
Analysis type MS
Chromatography type GC
Chromatography system Agilent
Column Restek Rtx-5Sil (30m x 0.25mm,0.25um)
MS Type EI
MS instrument type GC Ion Trap
MS instrument name Varian 210-MS GC Ion Trap
Ion Mode POSITIVE
Units Counts

Chromatography:

Chromatography ID:CH000659
Instrument Name:Agilent
Column Name:Restek Rtx-5Sil (30m x 0.25mm,0.25um)
Column Pressure:7.7 PSI (initial condition)
Column Temperature:50 - 330°C
Flow Rate:1 ml/min
Injection Temperature:50°C ramped to 250°C by 12°C/s
Sample Injection:0.5µl
Oven Temperature:50°C for 1 min, then ramped at 20°C/min to 330°C, held constant for 5 min
Transferline Temperature:230°C
Washing Buffer:Ethyl Acetate
Sample Loop Size:30 m length x 0.25 mm internal diameter
Randomization Order:Excel generated
Chromatography Type:GC

MS:

MS ID:MS000821
Analysis ID:AN000923
Instrument Name:Varian 210-MS GC Ion Trap
Instrument Type:GC Ion Trap
MS Type:EI
Ion Mode:POSITIVE
Ion Source Temperature:250°C
Ionization Energy:70eV
Mass Accuracy:Nominal
Source Temperature:250°C
Scanning Cycle:17 Hz
Scanning Range:85-500
Skimmer Voltage:1850 V
  logo