Return to study ST001191 main page

MB Sample ID: SA082721

Local Sample ID:NEG S-3
Subject ID:SU001258
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001258
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
NEG S-3SA082721FL012572SampleTreatment

Collection:

Collection ID:CO001252
Collection Summary:Total metabolites was extracted from the per group cell (~1x10e7) using 1 ml of methanolic acetonitrile aqueous solution (2:2:1, v/v), vortex for 60 s, hypothermia for 30 min, 2 times, place the protein for 1 h at -20 ° C, centrifuge at 14000 rcf for 20 min at 4 ° C, and freeze the supernatant. -80 ° C to save the sample
Sample Type:Tumor cells

Treatment:

Treatment ID:TR001273
Treatment Summary:After cells growth in 37°C for 12 h, 0.25mg/mL ginsenosides was fed of each well and continue cultured with for 12h

Sample Preparation:

Sampleprep ID:SP001266
Sampleprep Summary:Total metabolites was extracted from the per group cell (~1x10e7) using 1 ml of methanolic acetonitrile aqueous solution (2:2:1, v/v), vortex for 60 s, hypothermia for 30 min, 2 times, place the protein for 1 h at -20 ° C, centrifuge at 14000 rcf for 20 min at 4 ° C, and freeze the supernatant. -80 ° C to save the sample

Combined analysis:

Analysis ID AN001983
Analysis type MS
Chromatography type HILIC
Chromatography system Agilent 1290
Column
MS Type ESI
MS instrument type QTOF
MS instrument name ABI Sciex 5600 TripleTOF
Ion Mode NEGATIVE
Units intensity

Chromatography:

Chromatography ID:CH001431
Instrument Name:Agilent 1290
Column Temperature:25 ° C
Flow Rate:0.3 mL/min
Solvent A:100% water; 25 mM ammonium acetate
Solvent B:100% acetonitrile
Chromatography Type:HILIC

MS:

MS ID:MS001836
Analysis ID:AN001983
Instrument Name:ABI Sciex 5600 TripleTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The ESI source conditions after HILIC chromatographic separation are as follows: Ion Source Gas1 (Gas1): 60, Ion Source Gas 2 (Gas 2): 60, Curtain gas (CUR): 30, source temperature: 600 ° C, Ion Sapary Voltage Floating (ISVF) ± 5500 V (Positive and negative modes); TOF MS scan m/z range: 60-1000 Da, product ion scan m/z range: 25-1000 Da, TOF MS scan accumulation time 0.20 s/spectra, product ion scan accumulation time 0.05 s/spectra; secondary mass spectrometry is obtained using information dependent acquisition (IDA), and uses high sensitivity mode, Declustering potential (DP): ±60 V (both positive and negative modes), Collision Energy: 35±15 eV, IDA settings are as follows Exclude isotopes within 4 Da, Candidate ions to monitor per cycle: 6
Ion Mode:NEGATIVE
  logo