Return to study ST001434 main page
MB Sample ID: SA121890
Local Sample ID: | CTRL_05 |
Subject ID: | SU001508 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU001508 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
CTRL_05 | SA121890 | FL014907 | PBS | Antibody Group |
Collection:
Collection ID: | CO001503 |
Collection Summary: | Liver were collected after mice sacrifice, frozen in liquid N2 and store at -80°C until the day of analysis. |
Sample Type: | Liver |
Treatment:
Treatment ID: | TR001523 |
Treatment Summary: | LDLR-/-mice under high fat diet were injected with mA12-IgG2b and PBS or a B1-8 IgG2b isotype as control antibody |
Sample Preparation:
Sampleprep ID: | SP001516 |
Sampleprep Summary: | Frozen liver tissues were lysed in 0.5X PBS (sample:solvent 1:10 ratio) containing 1 mg/mL butylhydroxytoluene (BHT) solution in methanol (proportion 200 µL per g of tissue), with FastPrep-24 5G instrument (MP Biomedicals, USA). 25 µL aliquots of homogenate were collected and stored at -80°C until lipidomic extraction. Tissue homogenates were thawed and extracted with methyl-tert-butylether (MTBE) as described in [Matyash, V., et al., Lipid extraction by methyl-tert-butyl ether for high-throughput lipidomics. Journal of lipid research, 2008. 49(5): p. 1137-46]. 900 µL of organic phase were dried-out in speedvac and resuspended in 50 µL of ACN:H2O (20:80, v:v) just before injection. |
Combined analysis:
Analysis ID | AN002396 | AN002397 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Agilent mRP-Recovery C18 column (100 x 0.5mm,5um) | Agilent mRP-Recovery C18 column (100 x 0.5mm,5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap | Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | peak area | peak area |
Chromatography:
Chromatography ID: | CH001761 |
Instrument Name: | Thermo Dionex Ultimate 3000 |
Column Name: | Agilent mRP-Recovery C18 column (100 x 0.5mm,5um) |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS002237 |
Analysis ID: | AN002396 |
Instrument Name: | Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS was operating in full scan mode from 70 to 1700 m/z at 60000 resolution. Data processing was carried-out using Compound Discoverer (ThermoFisher; USA) with the Metaboprofiler node. |
Ion Mode: | POSITIVE |
MS ID: | MS002238 |
Analysis ID: | AN002397 |
Instrument Name: | Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS was operating in full scan mode from 70 to 1700 m/z at 60000 resolution. Data processing was carried-out using Compound Discoverer (ThermoFisher; USA) with the Metaboprofiler node. |
Ion Mode: | NEGATIVE |